7 Maintenance
42
Version: 2.3.0
MS202E
H-850 Hexapod Microrobot
Accessories
Transport safeguard (p. 19)
Original packaging (p. 9)
Electrostatic dissipative film
Strapping tape
Stretch film
7.2.1
Attaching the Transport Safeguard
Attaching the transport safeguard for the H-850.x2 and .x2V models
1.
Command motion of the hexapod to the transport position:
X = Y = U = V = 0
Z = -23
W = -6
2.
Uninstall the hexapod system:
a)
Remove the load from the motion platform of the hexapod.
b)
Switch the controller off.
c)
Remove the data transmission cable and the power supply cable from the controller
and the hexapod.
d)
Loosen the six M6x30 screws used to fix the hexapod on the underlying surface.
e)
Remove the six M6x30 screws.
Figure 15: Transport safeguard on the motion platform
1
Transport safeguard
2
Motion platform
3