4.1.2. CALIBRATE
The CALIBRATE item can calibrate the camera.
■
Execute calibration
The procedure for executing calibration is explained below.
①
Set the FRAME RATE and SHUTTER with the remote controller's ↑↓ keys.
②
Shield the lens using the lens cap. Since the black image at this time will be used as the
correction reference, verify that the lens is completely shielded and that no light is leaking
into the sensor.
③
Press the remote controller's MENU key to display the menu.
④
Using the remote controller's ARROW keys, select the CALIBRATE menu, then select the
CALIBRATE menu from the submenu.
⑤
With the remote controller's ↑↓ keys, move to ON, verify that the lens is shielded and then
press the remote controller's ENTER key.
⑥
Calibration finishes executing with the operation above.
⑦
Remove the lens cap and verify that the image is displayed correctly.