background image

08/2020 

Compliance with Standards 

PhoXi 3D Scanners conforms with the following standards and test specifications. The test criteria under which 
were PhoXi 3D Scanners certified are stated in the standards. Please note that the certification status may 

change without notification. Consult your local Photoneo representative if you need additional information 

related to the latest listing of exact approvals. 

Declaration of Conformity 

With Directive 2001/95/EC on General Product Safety and Directive 2014/30/EU on Electromagnetic 
Compatibility 

Manufacturer: 

Business name

Photoneo s.r.o. 

Registered seat:

Jamnického 3, Bratislava 841 05, Slovak Republic 

Identification number:

47353309 

Tax ID:

2023884907 

EU VAT ID:

SK2023884907 

Contact:

[email protected]

, +421 948 766 598 

Product​

 (subject of Declaration): 

Photoneo® PhoXi® 3D Scanner  

Following the development and testing of the Product throughout 2015 up until now, hereby the Manufacturer 
declares that his Product complies with the requirements and limitations as stated in the Directive 2001/95/EC 

on General Product Safety and in the Directive 2014/30/EU on Electromagnetic Compatibility. 

The Declaration of Conformity is issued under the sole responsibility of the Manufacturer. It relies on testing 
provided by: 

Research Institute of Posts and Telecommunications, Testing and Metrology Division - Test Report 
22/602/2020/Eng 

Lasermet Limited (Bournemouth UK), Laser Classification Reports to EN 60825-1:2014 - No. 1830, 1997b 

and 1962 

Technical Testing Institute in Piestany / Technický skúšobný ústav Piešťany (dedicated Product 

Certification Body) - Conformity Certificate No. 181299001 

Rhein Tech Laboratories, Inc. - FCC Class B DoC Report No. 2017262DOC 

[email protected]

PhoXi 3D Scanner - User Manual and Installation Instructions

31/40 

Summary of Contents for PhoXi L

Page 1: ...PhoXi 3D Scanner User Manual and Installation Instructions...

Page 2: ...notices are graded according to the degree of danger WARNING Indicates that death or severe personal injury may result if proper precautions are not taken CAUTION When a safety alert symbol is shown...

Page 3: ...Use of Photoneo Products Please note the following WARNING Photoneo products may only be used in accordance with relevant technical documentation If products and components from other manufacturers a...

Page 4: ...automation Scope of the Manual This manual describes the following products Photoneo PhoXi 3D Scanner Trademarks All names identified by are registered trademarks of Photoneo s r o The remaining trade...

Page 5: ...and Wiring 16 Configuration 17 PhoXi Control 17 Hardware Parameters 19 Power Over Ethernet Connector 19 Powering Requirements 19 24 V Power Connector 20 Powering Requirements 20 Projection Unit 21 En...

Page 6: ...rotection 33 Warranty 33 Dimensions and Illustrations 34 Bottom View Mounting Plate 34 Bottom View Detail A 35 Front View Projection Unit and Camera Unit 36 Changelog 37 Contact Information 38 support...

Page 7: ...urface and sends this data to the user via Ethernet connection Communication with the Scanner should be at least 1 Gbps in order to prevent bottlenecks during the data transfer process To learn more a...

Page 8: ...eam it is recommended to locate the device in a restricted area and take measures to restrict laser light exposure to the surroundings Although diffuse reflections are not harmful users should remove...

Page 9: ...found above the warning labels Label specifying wavelength average power pulse energy and pulse length of the laser User on scanner models M L XL Objects Suitable for Scanning The PhoXi 3D Scanners us...

Page 10: ...limited to mirrors and polished metals most liquids e g water oil moving objects translucent and transparent objects e g glass transparent plastic some hairy objects e g carpets support photoneo com...

Page 11: ...C output 33 6 W 56 V IEEE802 3at with power cable 3 m Ethernet cable M12 X male RJ45 male 5 m PUR NOTICE Software components are needed for operation of the Scanner See section Configuration for more...

Page 12: ...scanning distance is set between the Scanner and the scanned object and eliminate any potential obstacles Figure 2 Mounting plate 3 Connect the Scanner to the computer or local network and plug it int...

Page 13: ...cable to the PoE injector IN port 2 Connect the M12 X RJ45 cable to the scanner and to the PoE injector OUT port 3 Plug in the power cable of the PoE injector NOTICE It is recommended to use PoE conne...

Page 14: ...atus LEDs LED Name Color Description 1 POWER Green Red Off Power ON and OK Power ON power on processing unit not OK No power 2 STATUS Green Red Firmware ready HW fault 3 ETH1 Flashing green Green Off...

Page 15: ...a switch Figure 9 Connected to a switch The following network topology is not supported by the PhoXi 3D Scanners Scanner connected to a router Figure 10 Connecting the Scanner through router is not s...

Page 16: ...le always isolate low voltage logic type devices such as PhoXi 3D Scanners from devices that are high voltage and generate high electrical noise Carefully consider the routing of the wiring for the de...

Page 17: ...velopment with the API Calls to the API trigger the same response in the GUI as user inputs After triggering the scan by calling API method the application will execute the scan send it as an output o...

Page 18: ...Control from our website www photoneo com 3d scanning software For more information about the PhoXi Control application please refer to the PhoXi Control User Guide support photoneo com PhoXi 3D Scan...

Page 19: ...he M12 and RJ45 plug Powering Requirements PoE Standard IEEE802 3at Operating voltage U e DC min 55 V Residual ripple maximum of U e 0 5 Rated operating current I e I max 0 360 A 0 6 A Minimum Power 3...

Page 20: ...O_OUT 7 Blue OPTO_OUT_GND 8 Red OPTO_IN2 laser interlock signal devices with laser safety interlock needs to be ordered separately Powering Requirements Operating DC voltage U e U min U max 24 V 20 30...

Page 21: ...ble red light laser Wavelength 637 nm Peak power 18 6 mW Average power 340 W Pulse energy 18 6 J Pulse length 1 ms Environmental Conditions Transport Ambient temperature From 20 C to 50 C max gradient...

Page 22: ...verall operating temperature From 0 C to 45 C Humidity From 0 to 95 non condensing Atmospheric pressure From 1080 hPa to 660 hPa corresponding to an altitude of 1000 m tp 3500 m Maximum acceleration 2...

Page 23: ...nner being powered up or after 10 minutes of continuous scanning in the free run mode followed by 2 5 minutes of cool down to stabilize the temperature Datasheet Parameters Explanation Depth Map Resol...

Page 24: ...se The standard deviation of noise measured on a diffuse surface with 80 percent albedo The noise level describes the ability of the sensor to capture local surface details The noise distribution of o...

Page 25: ...rea at sweet spot 118 x 78 mm Point to point distance 0 055 mm Calibration accuracy 1 0 035 mm Temporal noise 1 0 030 mm Scanning time 250 2000 ms Dimensions 77 x 68 x 296 mm Baseline 85 mm Weight 900...

Page 26: ...ea at sweet spot 360 x 272 mm Point to point distance 0 174 mm Calibration accuracy 1 0 050 mm Temporal noise 1 0 050 mm Scanning time 250 2250 ms Dimensions 77 x 68 x 296 mm Baseline 230 mm Weight 90...

Page 27: ...rea at sweet spot 590 x 404 mm Point to point distance 0 286 mm Calibration accuracy 1 0 100 mm Temporal noise 1 0 100 mm Scanning time 250 2500 ms Dimensions 77 x 68 x 416 mm Baseline 350 mm Weight 9...

Page 28: ...ea at sweet spot 1082 x 772 mm Point to point distance 0 524 mm Calibration accuracy 1 0 200 mm Temporal noise 1 0 190 mm Scanning time 250 2750 ms Dimensions 77 x 68 x 616 mm Baseline 550 mm Weight 1...

Page 29: ...ea at sweet spot 1954 x 1459 mm Point to point distance 0 947 mm Calibration accuracy 1 0 500 mm Temporal noise 1 0 400 mm Scanning time 250 3000 ms Dimensions 77 x 68 x 941 mm Baseline 850 mm Weight...

Page 30: ...ere the scanner is used in an environment with lots of dust especially when the dust contains sharp or hard particles that could potentially damage the glass clean the glasses with specialized cleanin...

Page 31: ...of Declaration Photoneo PhoXi 3D Scanner Following the development and testing of the Product throughout 2015 up until now hereby the Manufacturer declares that his Product complies with the requireme...

Page 32: ...io frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not oc...

Page 33: ...lassification and requirements standard PhoXi 3D Scanners are primarily manufactured as laser class 3R devices Models M L and XL can be manufactured as laser class 2 devices The laser class was tested...

Page 34: ...08 2020 support photoneo com PhoXi 3D Scanner User Manual and Installation Instructions 34 40...

Page 35: ...08 2020 Dimensions and Illustrations Bottom View Mounting Plate Figure 22 Bottom view of PhoXi 3D Scanner support photoneo com PhoXi 3D Scanner User Manual and Installation Instructions 35 40...

Page 36: ...08 2020 Bottom View Detail A Figure 23 PhoXi 3D Scanner Detail A support photoneo com PhoXi 3D Scanner User Manual and Installation Instructions 36 40...

Page 37: ...08 2020 Front View Projection Unit and Camera Unit Figure 24 Projection unit and camera of PhoXi 3D Scanner support photoneo com PhoXi 3D Scanner User Manual and Installation Instructions 37 40...

Page 38: ...nel of the scanner Added connection schematics Different status LEDs 19 20 Section Hardware Parameters Pinouts and powering requirements for M12 X coded and M12 A coded connectors 21 Section Environme...

Page 39: ...adquarters Plyn rensk 1 821 09 Bratislava Slovak Republic Identification number 47 353 309 Tax ID 2023884907 EU VAT ID SK2023884907 Sales contact sales photoneo com 421 948 766 479 Technical support s...

Page 40: ...08 2020 Photoneo s r o Plyn rensk 1 82109 Bratislava Slovakia support photoneo com PhoXi 3D Scanner User Manual and Installation Instructions 40 40...

Reviews: