14.6 I/O Connector
14.6.2
Input Fault Detection
All inputs support a fault detection which signalises irregular conditions such as small
differential signals, shorts, opens, overvoltages and undervoltages. The fault condition of each
input can be read out by a software parameter. A fault condition remains active until it is
acknowledged by a software command.
Additionally Led S1 signalises the fault condition on LineIn0 and LineIn1. It turns on, when a
fault condition exists and turns automatically off when the input fault is resolved.
Section 14.2 lists the input range, the corresponding logic levels and fault conditions.
Unused inputs should be configured as single ended and the N-input must be
tight to ISO_GND in order not to get an I/O fault condition.
If an error condition has been detected on an input and signalized by the
Line-
Fault
parameter, it must be acknowledged by the
LineFaultAcknowledge
command
in order to use or reconfigure the corresponding input again.
Parameter
LineFaultUpdate
must be performed in order to update the error state.
14.6.3
Single-ended Line Input
LineIn0, LineIn1 or LineIn2 can be configured as single-ended input (Table 14.8 lists the
available standards). Fig. 14.5 shows two examples, how a single-ended configured input can
be used.
The inputs must be driven by a push-pull stage or an open drain output with a
pull-up resistor.
.
MAN093 08/2021 V1.1
105 of 143
Summary of Contents for MV4 Series
Page 8: ...CONTENTS 8 of 143 MAN093 08 2021 V1 1 ...
Page 12: ...1 Preface 12 of 143 MAN093 08 2021 V1 1 ...
Page 40: ...4 Image Acquisition 40 of 143 MAN093 08 2021 V1 1 ...
Page 42: ...5 Exposure Control 42 of 143 MAN093 08 2021 V1 1 ...
Page 52: ...6 Counter Timer 52 of 143 MAN093 08 2021 V1 1 ...
Page 64: ...10 Image Format Control 64 of 143 MAN093 08 2021 V1 1 ...
Page 66: ...11 Frame Rate 66 of 143 MAN093 08 2021 V1 1 ...
Page 82: ...12 Pixel Data Processing 82 of 143 MAN093 08 2021 V1 1 ...
Page 92: ...12 Pixel Data Processing 92 of 143 MAN093 08 2021 V1 1 ...
Page 96: ...13 Precautions 96 of 143 MAN093 08 2021 V1 1 ...
Page 120: ...16 Troubleshooting 120 of 143 MAN093 08 2021 V1 1 ...
Page 126: ...19 Support and Repair 126 of 143 MAN093 08 2021 V1 1 ...
Page 128: ...20 References 128 of 143 MAN093 08 2021 V1 1 ...