5.2 Trigger and Strobe
There is a bug in the single A/B trigger mode in some camera revisions (see Ap-
pendix B). In this case when the encoder position moves back and forth by a
small amount, the EncoderCounter is incremented and the decrement is some-
times omitted, leading to a wrong EncoderPosition indication in the camera.
Therefore the single A/B trigger mode should not be used in the affected ver-
sions. To have the same behaviour as the single trigger mode, but without the
bug, use the double A/B mode and double the value of
ABTriggerDivider
.
A
B
G r a y C o u n t e r
E n c o d e r C o u n t e r
T r i g g e r F w d
T r i g g e r B k w d
0
1
2
3
0
1
2
3
2
1
0
3
2
1
2
3
0
0
1
2
1
0
T r i g g e r F w d B k w d
1
1
Figure 5.8: Single A/B Mode
A
B
G r a y C o u n t e r
E n c o d e r C o u n t e r
T r i g g e r F w d
T r i g g e r B k w d
0
1
2
3
0
1
2
3
2
1
0
3
2
1
2
3
0
0
1
2
3
4
3
2
1
2
T r i g g e r B k w d
1
3
Figure 5.9: Double A/B Mode
A
B
G r a y C o u n t e r
E n c o d e r C o u n t e r
T r i g g e r F w d
T r i g g e r B k w d
0
1
2
3
0
1
2
3
2
1
0
3
2
1
2
3
0
0
1
2
3
4
5
6
7
6
5
4
3
2
1
2
3
4
T r i g g e r F w d B k w d
1
5
Figure 5.10: Quad A/B Mode
.
MAN066 12/2018 V1.1
45 of 103
Summary of Contents for MV1-R1280-50 Series
Page 6: ...CONTENTS 6 of 103 MAN066 12 2018 V1 1...
Page 10: ...1 Preface 10 of 103 MAN066 12 2018 V1 1...
Page 12: ...2 Introduction 12 of 103 MAN066 12 2018 V1 1...
Page 32: ...4 Product Specification 32 of 103 MAN066 12 2018 V1 1...
Page 76: ...6 Hardware Interface 76 of 103 MAN066 12 2018 V1 1...
Page 88: ...7 Software 88 of 103 MAN066 12 2018 V1 1...
Page 96: ...11 Support and Repair 96 of 103 MAN066 12 2018 V1 1...
Page 98: ...12 References 98 of 103 MAN066 12 2018 V1 1...
Page 102: ...B Camera Revisions 102 of 103 MAN066 12 2018 V1 1...