5 Counter & Timer
5.2.4
Timer Reset
The timer can be reset by a software command. It performs a software reset of the timer
counter and starts the timer immediately (change to state timer active), when trigger source is
set to off; otherwise it goes into the state timer trigger wait.
5.2.5
Timer Trigger Source
The timer trigger source selects the events that will be the used to reset and to start the timer.
The following list of signals are available:
Off
Disables the timer trigger.
Acquisition Trigger
Starts with the reception of the acquisition trigger event.
Acquisition Start
Starts with the reception of the acquisition start event.
Acquisition End
Starts with the reception of the acquisition end event.
FrameTrigger
Starts with the reception of the frame trigger event.
Frame Start
Starts with the reception of the frame start event.
Frame End
Starts with the reception of the frame end event.
Frame Burst Start
Starts with the reception of the frame burst start event.
Frame Burst End
Starts with the reception of the frame burst end event.
Exposure Start
Starts with the reception of the exposure start event.
Exposure End
Starts with the reception of the exposure end event.
User Output 0 ... 7
Starts when the selected user output bit is set to 1.
Counter 0 ... 3 Start
Starts with the reception of the chosen counter start event.
Counter 0 ... 3 End
Starts with the reception of the chosen counter end event.
Timer 0 ... 3 Start
Starts with the reception of the chosen timer start event.
Timer 0 ... 3 End
Starts with the reception of the chosen timer end event.
Action 0 ... 3
Starts with the reception of the chosen action signal event.
Software Signal Pulse 0 ... 7
Starts with the reception of chosen software signal pulse event
(see Section 4.7).
Line Input
Starts when the specified counter trigger activation condition is met on the chosen
line.
Line input source has additionally a activation configuration, which needs to be set
accordingly. Following configuration values are available:
Rising Edge
Timer starts with the rising edge on the selected line input.
Falling Edge
Timer starts with the falling edge on the selected line input.
Both Edges
Timer starts with any edge on the selected line input.
A self re-trigger timer can be configured, when the trigger source is set to its
own timer end event. The timer needs a software reset in order to start the self
re-trigger mode.
46 of 111
MAN078 12/2018 V1.1
Summary of Contents for MV0 CMOSIS Series
Page 10: ...1 Preface 10 of 111 MAN078 12 2018 V1 1...
Page 38: ...4 Image Acquisition 38 of 111 MAN078 12 2018 V1 1...
Page 52: ...8 Image Format Control 52 of 111 MAN078 12 2018 V1 1...
Page 78: ...12 Precautions 78 of 111 MAN078 12 2018 V1 1...
Page 88: ...14 Mechanical Considerations 88 of 111 MAN078 12 2018 V1 1...
Page 90: ...15 Troubleshooting 90 of 111 MAN078 12 2018 V1 1...
Page 96: ...18 Support and Repair 96 of 111 MAN078 12 2018 V1 1...