
C.1 Acquisition
5.
The number of frame within a burst must be set by parameter
AcquisitionBurstFrameCount
parameter.
6.
Set the parameter
EnAcquisitionFrameRate
to
False
if the frames within a burst must be
acquired as fast as possible.
7.
If the frames within a burst must be acquired with a certain speed, set the parameter
EnAcquisitionFrameRate
to
True
and configure either
AcquisitionFrameTime
or
AcquisitionFrameRate
accordingly.
8.
The required image
Width
and
Height
must be set.
9.
The required
PixelFormat
must be set.
10.
AcquisitionMode
must be set to
Continuous
.
11. The software command
AcquisitionStart()
must be applied.
It might be necessary to adjust the polarity of the
Line0
input signal. This can be done by the
parameter
LineInvert
in the section DigitalIOControl.
C.1.5
Triggered controlled exposure mode
The exposure time can be controlled by an externally applied trigger signal on LineIn input.
The following configuration procedure shows how to set the camera in the triggered
controlled exposure mode:
1.
Parameter
ExposureMode
must be set to
TriggerControlled
.
2.
The TriggerMode of
ExposureStart
and
ExposureEnd
trigger must be set to
On
. The
AcquisitionStart
,
FrameStart
and
FrameBurstStart
trigger must be set to
Off
.
3.
The
TriggerSource
of the
ExposureStart
trigger must be set to
Line0
.
4.
The
TriggerActivation
of the
ExposureStart
trigger must be set to
RisingEdge
.
5.
The
TriggerSource
of the
ExposureEnd
trigger must be set to
Line0
.
6.
The TriggerActivation of the
ExposureEnd
trigger must be set to
FallingEdge
.
7.
TriggerDelay
and
TriggerDivider
of the
ExposureStart
and
ExposureEnd
trigger must be set
accordingly.
8.
The required image
Width
and
Height
must be set.
9.
The required
PixelFormat
must be set.
10.
AcquisitionMode
must be set to
Continuous
.
11. The software command
AcquisitionStart()
must be applied.
MAN078 12/2018 V1.1
105 of 111
Summary of Contents for MV0 CMOSIS Series
Page 10: ...1 Preface 10 of 111 MAN078 12 2018 V1 1...
Page 38: ...4 Image Acquisition 38 of 111 MAN078 12 2018 V1 1...
Page 52: ...8 Image Format Control 52 of 111 MAN078 12 2018 V1 1...
Page 78: ...12 Precautions 78 of 111 MAN078 12 2018 V1 1...
Page 88: ...14 Mechanical Considerations 88 of 111 MAN078 12 2018 V1 1...
Page 90: ...15 Troubleshooting 90 of 111 MAN078 12 2018 V1 1...
Page 96: ...18 Support and Repair 96 of 111 MAN078 12 2018 V1 1...