13
Hardware Interface
13.1
Absolute Maximum Ratings
Parameter
Value
Camera Control Input Signal Voltage Single Ended
0 V ... +24 V
Camera Control Output Signal Voltage Single Ended
0 V ... +24 V
Camera Control Output Signal Output Current Single Ended
0.1 A
Camera Control Output Signal Output Power Single Ended
0.15 W
ESD Contact Discharge Camera Control Signals
4 kV
ESD Air Discharge Camera Control Signals
8 kV
Fast Transients/Bursts Data and Camera Control Signals
2 kV
Surge immunity Data and Camera Control Signals
1 kV
Maximum Installation Altitude
2000m above sea level
Table 13.1: Absolute Maximum Ratings
13.2
Electrical Characteristics
Parameter
Value
Camera Control Input Single Ended
+5 V ... +20 V
Table 13.2: Electrical Characteristics
13.3
GigE Camera Connector
The GigE cameras are interfaced to external components via
•
an x-coded M12 connector to power the camera (PoE) and to transmit configuration,
image data and trigger.
•
a 4 pole Binder M5 x 0.5 connector for one I/O input and one I/O output.
The connectors are located on the back of the camera. Fig. 13.1 shows the plugs and the status
LED which indicates camera operation.
13.4
Power Over Ethernet (PoE)
Device: PoE compliant according to IEEE 802.3af standard Class: 2: (3.84-6.49W) supported
Mode: Mode A and Mode B Maximum working voltage according to Standard: 57V at PD side
MAN082 09/2019 V1.0
93 of 125
Summary of Contents for MV0 3D06 Series
Page 10: ...1 Preface 10 of 125 MAN082 09 2019 V1 0...
Page 20: ...3 Product Specification 20 of 125 MAN082 09 2019 V1 0...
Page 38: ...4 Image Acquisition 38 of 125 MAN082 09 2019 V1 0...
Page 48: ...5 Counter Timer 48 of 125 MAN082 09 2019 V1 0...
Page 58: ...9 Image Format Control 58 of 125 MAN082 09 2019 V1 0...
Page 62: ...10 Frame Rate 62 of 125 MAN082 09 2019 V1 0...
Page 88: ...11 Image Data Processing 88 of 125 MAN082 09 2019 V1 0...
Page 92: ...12 Precautions 92 of 125 MAN082 09 2019 V1 0...
Page 100: ...13 Hardware Interface 100 of 125 MAN082 09 2019 V1 0...
Page 104: ...14 Mechanical Considerations 104 of 125 MAN082 09 2019 V1 0...
Page 106: ...15 Troubleshooting 106 of 125 MAN082 09 2019 V1 0...
Page 112: ...18 Support and Repair 112 of 125 MAN082 09 2019 V1 0...
Page 114: ...19 References 114 of 125 MAN082 09 2019 V1 0...