5 Counter & Timer
5.2.3
Timer Active, -Start and -End Signal
Timer Active
An asserted timer active signal indicates, that the timer has started counting the
configured duration period. The timer active signal is internally routed to the I/O control
block and can there be selected for output on the physical output line or on one of the
available leds.
Timer Start
The timer start is an event, which is generated, when the timer starts with the
timer duration period.
Timer End
The timer end is an event, which is generated, when the timer arrives its configured
timer duration value.
The timer start and end event signals can be used to trigger other blocks, like counter, timer,
acquisition, frame or exposure control.
5.2.4
Timer Reset
The timer can be reset by a software command. It performs a software reset of the timer
counter and starts the timer immediately (change to state timer active), when trigger source is
set to off; otherwise it goes into the state timer trigger wait.
5.2.5
Timer Trigger Source
The timer trigger source selects the events that will be the used to reset and to start the timer.
The following list of signals are available:
Off
Disables the timer trigger.
Acquisition Trigger
Starts with the reception of the acquisition trigger event.
Acquisition Start
Starts with the reception of the acquisition start event.
Acquisition End
Starts with the reception of the acquisition end event.
FrameTrigger
Starts with the reception of the frame trigger event.
Frame Start
Starts with the reception of the frame start event.
Frame End
Starts with the reception of the frame end event.
Frame Burst Start
Starts with the reception of the frame burst start event.
Frame Burst End
Starts with the reception of the frame burst end event.
Exposure Start
Starts with the reception of the exposure start event.
Exposure End
Starts with the reception of the exposure end event.
User Output 0 ... 7
Starts when the selected user output bit is set to 1.
Counter 0 ... 3 Start
Starts with the reception of the chosen counter start event.
Counter 0 ... 3 End
Starts with the reception of the chosen counter end event.
Timer 0 ... 3 Start
Starts with the reception of the chosen timer start event.
Timer 0 ... 3 End
Starts with the reception of the chosen timer end event.
Encoder
Starts with the reception of the encoder trigger event.
46 of 125
MAN082 09/2019 V1.0
Summary of Contents for MV0 3D06 Series
Page 10: ...1 Preface 10 of 125 MAN082 09 2019 V1 0...
Page 20: ...3 Product Specification 20 of 125 MAN082 09 2019 V1 0...
Page 38: ...4 Image Acquisition 38 of 125 MAN082 09 2019 V1 0...
Page 48: ...5 Counter Timer 48 of 125 MAN082 09 2019 V1 0...
Page 58: ...9 Image Format Control 58 of 125 MAN082 09 2019 V1 0...
Page 62: ...10 Frame Rate 62 of 125 MAN082 09 2019 V1 0...
Page 88: ...11 Image Data Processing 88 of 125 MAN082 09 2019 V1 0...
Page 92: ...12 Precautions 92 of 125 MAN082 09 2019 V1 0...
Page 100: ...13 Hardware Interface 100 of 125 MAN082 09 2019 V1 0...
Page 104: ...14 Mechanical Considerations 104 of 125 MAN082 09 2019 V1 0...
Page 106: ...15 Troubleshooting 106 of 125 MAN082 09 2019 V1 0...
Page 112: ...18 Support and Repair 112 of 125 MAN082 09 2019 V1 0...
Page 114: ...19 References 114 of 125 MAN082 09 2019 V1 0...