C.2 Timer
9.
The required
PixelFormat
must be set.
10.
AcquisitionMode
must be set to
Continuous
.
11. The software command
AcquisitionStart()
must be applied.
It might be necessary to adjust the polarity of the
Line0
input signal. This can be done by the
parameter
LineInvert
in the section DigitalIOControl.
C.1.5
Trigger controlled exposure mode
The exposure time can be controlled by an externally applied trigger signal on LineIn input.
The following configuration procedure shows how to set the camera in the trigger controlled
exposure mode:
1.
Parameter
ExposureMode
must be set to
TriggerControlled
.
2.
The TriggerMode of
ExposureStart
and
ExposureEnd
trigger must be set to
On
. The
AcquisitionStart
,
FrameStart
and
FrameBurstStart
trigger must be set to
Off
.
3.
The
TriggerSource
of the
ExposureStart
trigger must be set to
Line0
.
4.
The
TriggerActivation
of the
ExposureStart
trigger must be set to
RisingEdge
.
5.
The
TriggerSource
of the
ExposureEnd
trigger must be set to
Line0
.
6.
The TriggerActivation of the
ExposureEnd
trigger must be set to
FallingEdge
.
7.
TriggerDelay
and
TriggerDivider
of the
ExposureStart
and
ExposureEnd
trigger must be set
accordingly.
8.
The required image
Width
and
Height
must be set.
9.
The required
PixelFormat
must be set.
10.
AcquisitionMode
must be set to
Continuous
.
11. The software command
AcquisitionStart()
must be applied.
C.2
Timer
There are four general purpose timers available. The following sections show some use cases,
how the timers can be used.
C.2.1
Strobe Signal Output
The timer can be used to generate a pulse with a certain width on the LineOut output together
with every exposure cycle in order to control an external light. The following procedure shows,
how to configure one of the timer for this purposes:
1.
Select one of the four available timers by setting of the
TimerSelector
to
Timer0
,
Timer1
,
Timer2
or
Timer3
.
2.
Select the timer trigger source. Set
TimerTriggerSource
to
ExposureStart
.
3.
Parameter
TimerTriggerActivation
can be ignored. This configuration is only necessary,
when
Line0
input is selected as a trigger source.
4.
Configure the necessary
TimerDuration
value and the
TimerDelay
value.
At this stage, the configured timer generates a pulse of a certain width and after a certain
delay every time, when a new exposure cycle starts, which is indicated by the internally
available
TimerActive
status. This signal must be connected to the camera LineOut output,
which can be done in the DigitalIOControl section:
MAN085 04/2021 V1.3
145 of 151
Summary of Contents for Luxima DR4-D1280-L01-FB
Page 8: ...CONTENTS 8 of 151 MAN085 04 2021 V1 3...
Page 12: ...1 Preface 12 of 151 MAN085 04 2021 V1 3...
Page 42: ...4 Image Acquisition 42 of 151 MAN085 04 2021 V1 3...
Page 52: ...5 Counter Timer 52 of 151 MAN085 04 2021 V1 3...
Page 84: ...12 Pixel Data Processing 84 of 151 MAN085 04 2021 V1 3...
Page 94: ...12 Pixel Data Processing 94 of 151 MAN085 04 2021 V1 3...
Page 98: ...13 Precautions 98 of 151 MAN085 04 2021 V1 3...
Page 128: ...16 Troubleshooting 128 of 151 MAN085 04 2021 V1 3...
Page 134: ...19 Support and Repair 134 of 151 MAN085 04 2021 V1 3...
Page 136: ...20 References 136 of 151 MAN085 04 2021 V1 3...
Page 140: ...A Pinouts 140 of 151 MAN085 04 2021 V1 3...