MODEL

PART #

DESCRIPTION

 (All 50-60 Cycles)

TEMP

        RANGE**

INSULATION

CHAMBER

SIZE

CAPACITY

WEIGHT &

DIMENSIONS

Type 4 Series Model 

100˚ to 550˚F 

(38˚ to 288˚C) 

+/-25˚F (14˚C)

Adjustable 

Thermostat 

Control with 

Indicator Light 

2" 

Fiberglass

35" x 21" x 47" 

(89 cm x 53 cm x 

119 cm) 

Up to 24 12" or 

16 16" spools or 

coils 

450 lb (204 kg) 

45" x 29" x 55" 

(114 cm x 74 cm 

x 140 cm)

dryWIRE®

1205431

240/480V AC* @ 2500 watts with installed thermometer

dryWIRE®

1205430

240/480V AC* @ 2500 watts

*Operation on Direct Current (DC) will damage oven and void warranty.

**Average stabilized temperature @ 70˚F ambient temperature.

OPERATING INSTRUCTIONS

dryWIRE® Flux Cored Electrode 

Wire Stabilization Ovens

www.

phx-international

.com

8711 West Port Avenue 

 Milwaukee, WI 53224 USA 

 Telephone: 414-973-3400 

 Fax: 414-973-3275

Phoenix International, Inc.

N5610275A

dryWIRE

R

Summary of Contents for dryWIRE 1205431

Page 1: ...4 kg 45 x 29 x 55 114 cm x 74 cm x 140 cm dryWIRE 1205431 240 480V AC 2500 watts with installed thermometer dryWIRE 1205430 240 480V AC 2500 watts Operation on Direct Current DC will damage oven and v...

Page 2: ...eating elements Momentary rotation past desired temperature setting may be necessary to activate the indicator light in order to locate it for indexing purposes Thermostat is accurate to 25 F 14 C at...

Page 3: ...e of both feet attach the hold downs found with original packaging to each of the ackermanns SECURING OVEN METHOD 2 1 Making sure that there will be a minimum of 4 3 4 12 1 cm from the back of the ove...

Page 4: ...E SETTING OFF 1 Check thermostat operation as in number 3 Oven Fails to Operate No Heat 2 If thermostat continues to operate satisfactorily recalibrate per Checking Thermostat Calibration section in t...

Page 5: ...tment or re calibration is not needed unless the thermostat has been mishandled in transit or changed or abused while in service To Check Calibration 1 Use a good grade mercury thermometer to check te...

Page 6: ...7550280 2 Vent Cover 1 2605700 Thermostat Cover 1 5110110 Shelf Bracket 8 2751910 Heating Element Guard 1 2751580 4 Thermostat Kit 1257080 Thermostat 1 Thermostat Knob 1 Conduit Kit 1257150 Conduit Bo...

Page 7: ...damage to electrodes and or welded products resulting from the use of this table Temperatures and times shown are recommended and are not guaranteed to be correct Eliminate expensive rework and prote...

Page 8: ...bsite at www phx international com Take your treated electrodes with you Safetube Industrial Storage Container Short term portable storage of electrodes Pressure fitted O ring maintains watertight sea...