IB IL 24 PSDO 8-PAC
PHOENIX CONTACT
7619_en_05
1.6
Directives and standards
The manufacturers and operators of machines and systems, in which the
IB IL 24 PSDO 8-PAC module is used, are responsible for adhering to all applicable direc-
tives and legislation.
For the standards observed by the module, please refer to the certificate issued by the ap-
proval body and the EC declaration of conformity. These documents are available on the
.
1.7
Intended use
Only use the INTERBUS-Safety, SafetyBridge or PROFIsafe system in accordance with the
instructions in this section.
The IB IL 24 PSDO 8-PAC safety module is designed exclusively for use in an
INTERBUS-Safety, SafetyBridge or PROFIsafe system.
It can only perform its safety-related tasks within the system if it has been integrated into the
execution process correctly and in such a way as to avoid errors.
You must observe all information in this user manual as well as in the documents listed in
“Documentation” on page 13. In particular, only use the module according to the technical
data and ambient conditions specified in Section 10, "Technical data and ordering data" on
Page 82 and onwards.
Within an INTERBUS-Safety, SafetyBridge or PROFIsafe system, the safety module can be
used to achieve safety functions with the following requirements depending on the condi-
tions of use:
–
Up to SIL 3 according to standard EN 61508
–
Up to SILCL 3 according to standard EN 62061
–
Up to Cat. 4/PL e according to standard EN ISO 13849-1
It is designed for connecting single-channel or two-channel actuators, which can be used in
association with safety technology.
For example, the module can be used in the following applications:
–
Safety circuits according to EN 60204 Part 1
–
Safe shutdown of contactors, motors (24 V DC), valves, ohmic, inductive, and capaci-
tive loads
The module is
not
suitable for applications in which stop category 1 also has to be observed
in the event of an error.
For additional information about stop categories, please refer to the INTERBUS-Safety
system description UM EN INTERBUS-SAFETY SYS.
Summary of Contents for IB IL 24 PSDO 8-PAC
Page 1: ...User manual IB IL 24 PSDO 8 PAC Inline module with safe digital outputs...
Page 16: ...IB IL 24 PSDO 8 PAC 16 112 PHOENIX CONTACT 7619_en_05...
Page 32: ...IB IL 24 PSDO 8 PAC 32 112 PHOENIX CONTACT 7619_en_05...
Page 38: ...IB IL 24 PSDO 8 PAC 38 112 PHOENIX CONTACT 7619_en_05...
Page 54: ...IB IL 24 PSDO 8 PAC 54 112 PHOENIX CONTACT 7619_en_05...
Page 68: ...IB IL 24 PSDO 8 PAC 68 112 PHOENIX CONTACT 7619_en_05...
Page 78: ...IB IL 24 PSDO 8 PAC 78 112 PHOENIX CONTACT 7619_en_05...
Page 80: ...IB IL 24 PSDO 8 PAC 80 112 PHOENIX CONTACT 7619_en_05...
Page 90: ...IB IL 24 PSDO 8 PAC 90 112 PHOENIX CONTACT 7619_en_05...
Page 106: ...IB IL 24 PSDO 8 PAC 106 112 PHOENIX CONTACT 7619_en_05...