1. Description

 

The 

 

FL MC 100BASE-T/FO G1300

 

 medium 

converter provides a high level of noise immunity and a 
long transmission range in industrial applications by 
converting the 100 BASE-TX Ethernet interface to 
optical fibers corresponding to the FX standard.

The device can be operated individually as well as in 

connection with other Factory Line devices (Factory 
Line unit). The supply voltage is 24 V DC. In the FL unit, 
the supply voltage is supplied to all the connected 
devices via a backplane integrated into the base of the 
device. In individual operation, the supply is provided 
using plug-in screw-cage terminal blocks.

The converter has a link monitoring function, which 

separately indicates/monitors the operability of the 
cable connection and the connected devices for the 
twisted pair and optical fiber channels.  

If long distances are to be covered or if an existing 

glass fiber installation is used, the 

 

FL MC 100BASE-T/

FO G1300

 

 converter covers distances up to 10,000 m  

with 62,5/125 

 

µ

 

m or 6400 m with 50/125 

 

µ

 

m using 

multimode glass fiber. The connection corresponds to 
the SC- DUPLEX standard.

The medium converter conforms to the 

specifications of standards IEEE 802.3 and ISO/IEC 
68802.3.

 

Should you have any technical questions, please 
contact us:
Technical Service: 800-322-3225
FAX: (717) 948-3475
E-mail: [email protected]

Optical fiber

 

Medium Converter
FL MC 100BASE-T/FO G1300

 

Headquarters: Phoenix Contact Inc. • P.O. Box 4100 • Harrisburg, PA 17111-0100

Phone (717) 944-1300 • Fax (717) 944-1625 • www.phoenixcon.com

Summary of Contents for FL MC 100BASE-T/FO G1300

Page 1: ...ing function which separately indicates monitors the operability of the cable connection and the connected devices for the twisted pair and optical fiber channels If long distances are to be covered or if an existing glass fiber installation is used the FL MC 100BASE T FO G1300 converter covers distances up to 10 000 m with 62 5 125 µm or 6400 m with 50 125 µm using multimode glass fiber The conne...

Page 2: ...operation FL MC 100BASE T FO G1300 Type Order No Pcs Pkt FL MC 100BASE T FO G1300 27 44 76 2 1 ME BUS SA NS35 PSM LWL GDM 50 125 PSM LWL GDO 50 125 FL CAT5 HEAVY FL CAT5 FLEX FL PLUG RJ45 GR 2 FL PLUG RJ45 GN 2 FL CRIMPTOOL FL CAT5 TERMINAL BOX 29 35 95 9 27 99 32 2 27 99 43 2 27 44 81 4 27 44 83 0 27 44 85 6 27 44 57 1 27 44 86 9 27 44 61 0 1 1 1 1 1 1 1 1 1 FL MC 100BASE T FO G1300 for glass fib...

Page 3: ...g characteristics within the specified limits 2 Criterion B Temporary adverse effects on the operating characteristics that the device corrects independently Class A Industrial application without special installation measures Free from substances which would hinder coating with paint or varnish according to VW Audi and Seat specification EN 60 068 2 6 5g 1 5 h in xyz direction EN 60 068 2 27 stor...

Page 4: ...erate green 6 LED Link status FO port green 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 0 0 0 7 A 0 0 5 Figure 06 Medium Converter FL MC 100BASE T FO G1300 3 Function Elements 7 LED Receiving data FO port yellow 8 LED Link status TP port green 9 LED Receiving data twisted pair port yellow 10 100Base T connection TP port 11 Optical fiber connection receiver 12 Optical fiber connection sender ...

Page 5: ... 07 3 Push the module from the front towards the mounting surface 4 Once the module has been snapped on properly check that it is fixed securely on the DIN rail 5 Snap the other modules to be contacted onto the DIN rail side by side Only mount and remove modules when the power supply is disconnected When connecting the supply voltage for operation in a FL unit please refer to the notes Attention D...

Page 6: ...ower supply unit can be connected to terminals US2 and GND to provide a redundant voltage supply Both US1 US2 voltages are forwarded on the backplane 5 2 Operation in an FL Unit 6 Twisted Pair Interface Twisted Pair Port 6 1 100Base T Interface The FL MC 100BASE T FO G1300 has an Ethernet interface on the front in RJ45 format to which only twisted pair cables with an impedance of 100 Ω can be conn...

Page 7: ...sh between the two cable types green bending protection bushings should be used for crossover cables and gray bending protection bushings for linear wired cables LINE 1 1 Line 1 1 gray protective caps CROSSOVER green protective caps PC RFC IBS gateway I O bus terminal module Switch Hub Medium converter PC RFC Cross Cross Cross Line Line Line IBS gateway Cross Cross Cross Line Line Line I O bus ter...

Page 8: ...g radii strain and pressure strengths must not be exceeded 7 2 LED Diagnostic Indicators Link Control Optical Fiber Path FO The line monitoring checks the connected cable segment for an interrupt To do this the partner must send link or data signals The LED green lights up if no error has occurred An interface that is not being used or a terminal device that is switched off is indicated as an erro...

Page 9: ...iber measuring instrument The sender must be operated in an ambient operating temperature from 20 30 C 68 86ºF The limit values already include the fluctuations caused by the temperature Measuring Optical Power For glass fibers adjust the measuring instrument to 1300 nm and the power measuring range to dBm Remove the RJ45 connector to interrupt data communication Apply the operating voltage to the...