Phoenix Contact Basicline 2 Series User Manual Download Page 1

User manual

UM EN BL2 ...100

Basicline 2 configurable industrial PCs 

Summary of Contents for Basicline 2 Series

Page 1: ...User manual UM EN BL2 100 Basicline 2 configurable industrial PCs...

Page 2: ...3101 1099306 BL2 BPC 7101 1099309 BL2 BPC 9101 1099311 BL2 PPC 2100 1105780 BL2 PPC 3100 1105781 BL2 PPC 7100 1105782 BL2 PPC 9100 1105783 BL2 PPC15 6 2101 1099318 BL2 PPC15 6 3101 1099319 BL2 PPC15 6...

Page 3: ...ata 5 3 Installation 7 3 1 Mounting 7 3 1 1 Wall mount BL2 BPC 100 7 3 1 2 DIN rail mount 9 3 1 3 Panel mount BL2 PPC 100 10 3 2 Interfaces 11 3 2 1 Power connection 12 3 2 2 Serial communication 13 3...

Page 4: ...BL2 100 2 36 PHOENIX CONTACT 4024_en_E...

Page 5: ...andards Any modifications to the systems can influence the EMC behavior This symbol indicates hazards that could lead to personal injury There are three signal words indicating the severity of a poten...

Page 6: ...o interference In this case the operator is obligated to implement appropriate measures 1 3 2 Product changes Changes or modifications to hardware and software of the device are not permitted Incorrec...

Page 7: ...BPC 3100 1105776 1 Industrial box PC configurable Intel Core i5 6300U processor 2 40 3 00 GHz BL2 BPC 7100 1105777 1 Industrial box PC configurable Intel Core i7 6600U processor 2 60 3 40 GHz BL2 BPC...

Page 8: ...ron processor N4200 1 10 2 50 GHz BL2 PPC 2100 1099331 1 Industrial panel PC with 21 5 in display Intel Core i3 6100U processor 2 30 GHz BL2 PPC 3100 1099332 1 Industrial panel PC with 21 5 in display...

Page 9: ...ke sure that there is adequate space around the heat sink to provide sufficient cooling 3 1 1 Wall mount BL2 BPC 100 Figure 3 1 Mounting dimensions BL2 BPC 1100 BL2 BPC 2100 NOTE Install the BL2 100 w...

Page 10: ...or Figure 3 2 and mark the locations of the holes on the mounting surface 2 Use the correct anchor type for the mounting surface and securely attach the BL2 BPC 100 to the wall Ensure that the attach...

Page 11: ...of the DIN rail 2 Rotate the BL2 BPC 100 down A against the lower edge of the DIN rail Press in B until the latch snaps closed 3 Secure the device on the rail with clamps 4 If necessary to remove rais...

Page 12: ...t 1 is properly positioned in the groove and against the panel 3 From the rear place the clamps 2 in the slots 3 on the display and slide the clamp to the left to lock it into the slot Clamps must be...

Page 13: ...2 RS 422 or RS 485 1 Functional earth ground screw 2 Power connector 3 Ethernet RJ45 ports 4 USB 3 0 connectors 5 USB 2 0 connectors 6 DisplayPort connectors 7 On off switch 8 Configurable RS 232 422...

Page 14: ...external displays The BL2 PPC 100 supports up to two external displays 3 2 1 Power connection A three position screw type COMBICON connector MSTB 2 5 3 STF 5 08 is provided for connecting power to th...

Page 15: ...ttings NOTE To comply with UL 61010 2 201 a safety extra low voltage SELV according to DIN EN 61131 as supply voltage is required This device is protection class I item of equipment UEFI is set to boo...

Page 16: ...enclosure rather than directly to the IPC To do this an appropriate length antenna cable 3 must be purchased separately The antenna or antenna cable threads onto the BL2 100 For external antenna moun...

Page 17: ...Figure 3 6 on page 11 Table 4 1 LED indications LED Indication Description PWR Green When 24 V DC is applied and the power switch is turned on SATA Flashes green Indicates data storage HDD or SSD act...

Page 18: ...BL2 100 16 36 PHOENIX CONTACT 4024_en_E...

Page 19: ...ge replacement Before beginning any mass storage replacement procedures use an external drive and make a copy of or backup the contents of the internal drive to be replaced Disconnect the external dri...

Page 20: ...nel 2 to the chassis 3 Gently pry the access panel away from the chassis using a flat screwdriver Turn the access panel over to protect the thermal pads 3 and set aside The drive tray should be visibl...

Page 21: ...1 for similar panel 6 Gently pry the adapter plate away from the chassis using a flat screwdriver Turn the adapter plate over keeping the connected cables in the opening to the display and set it on t...

Page 22: ...e tray BL2 BPC 100 shown 2 Lift the assembly off the circuit board and disconnect the ribbon cable not shown 3 Remove the four screws 4 securing the drive in the tray and slide the drive out of the tr...

Page 23: ...Pull the drive out of the socket and remove it 4 Insert the new drive into the socket at the same angle as the one that was removed Make sure the drive is fully seated in the socket 5 Secure the drive...

Page 24: ...e socket and remove it 4 Insert the new drive into the socket at the same angle as the one that was removed Make sure the drive is fully seated in the socket 5 Secure the drive with the washer and scr...

Page 25: ...humidity relative If equipped with wireless mini PCIe card option 10 90 non condensing 10 80 non condensing Weight BL2 BPC 1100 BL2 BPC 2100 BL2 BPC 3100 BL2 BPC 7100 BL2 BPC 9100 BL2 PPC 2100 with 1...

Page 26: ...A 2 8 A Power maximum 24 V maximum with no display with 15 6 in display with 18 5 in display with 21 5 in display 26 4 W 31 2 W 40 8 W 43 2 W 50 4 W 45 6 W 55 4 W 56 2 W 64 3 W 46 1 W 55 4 W 56 6 W 6...

Page 27: ...ory channels 2 2 2 2 2 Interfaces USB 2x Type A USB 2 0 2x Type A USB 3 0 Serial connection 1x D SUB 9 male UEFI selectable for RS 232 422 485 Super I O chipset Nuvoton NCT6106D Chipset Integrated Vid...

Page 28: ...uency range 2 4 GHz 5 GHz 2412 2472 Hz 5180 5825 Hz Data transfer rate 2 4 GHz 5 GHz Transmit power typical 2 4 GHz b 2 4 GHz g 5 GHz a 12 5 dBm Channel 1 14 5 dBm Channel 2 10 11 0 dBm Channel 11 13...

Page 29: ...7 x 367 mm Outside bezel dimensions W x H x D 562 x 382 x 9 mm Backlight life minimum 50000 hr Video signal DisplayPort DP Display data 18 5 inch display Overall dimensions including bezel W x H x D 4...

Page 30: ...Contrast ratio 500 1 View angle horizontal vertical CR 10 typ 85 80 Installation cutout dimensions W x H 401 x 296 mm Outside bezel dimensions W x H x D 417 x 312 x 6 mm Backlight life minimum 50000 h...

Page 31: ...ting 9 Figure 3 4 Panel cutout dimensions 10 Figure 3 5 Panel mounting clamps 10 Figure 3 6 Connectors and ports BL2 1100 BL2 2100 11 Figure 3 7 Connectors and ports BL2 3100 BL2 7100 BL2 9100 11 Figu...

Page 32: ...BL2 100 30 36 PHOENIX CONTACT 4024_en_E...

Page 33: ...X CONTACT 31 36 B 2 List of tables Section 3 Table 3 1 Display cutout dimensions 10 Table 3 2 Power connector 12 Table 3 3 RS 232 422 485 communication settings 13 Table 3 4 D SUB 9 pinout 13 Section...

Page 34: ...BL2 100 32 36 PHOENIX CONTACT 4024_en_E...

Page 35: ...out 10 D DIN rail mount BL2 BPC 9 Display cutout dimensions 10 D SUB 9 pinout 13 E External display 12 I Interfaces 11 L LEDs 15 M Mounting 7 P Panel mount BL2 PPC 10 Ports 11 Power 12 S Safety 3 Seri...

Page 36: ...BL2 100 34 36 PHOENIX CONTACT 4024_en_E...

Page 37: ...products in your specific application in particular with regard to observing the applicable standards and regulations All information made available in the technical data is supplied without any accom...

Page 38: ...products Subsidiaries If there are any problems that cannot be solved using the documentation please contact your Phoenix Contact subsidiary Subsidiary contact information is available at phoenixconta...

Reviews: