PSR-TRISAFE-S
2-2
PHOENIX CONTACT
103503_en_03
Hardware:
PSR-TRISAFE-S
The PSR-TRISAFE-S safety module offers 20 digital safe inputs for connecting a maximum
of 20 single-channel or 10 two-channel safety-related sensors and control devices.
The PSR-TRISAFE-S has 4 digital safe outputs, which are semiconductor outputs
(24 V DC/2 A (total current)). The outputs are designed to meet up to category 4 according
to EN 954-1.
Depending on the configuration, stop category 0 according to DIN EN 60204-1 can be
achieved for each output (see "Stop category 0" on page 2-4).
In addition, four signaling current paths, two test pulses at two outputs each, and two ground
switching outputs are available.
For more detailed information about the safety module, please refer to the device
description in Section 3.
Software:
SAFECONF
The PSR-TRISAFE-S safety module can only be configured and parameterized using the
SAFECONF safe configuration software, which is executed on a separate Windows
®
PC.
The software offers a graphical connection editor for this purpose. The safety logic can be
created here by graphically connecting prepared safe functions and functional blocks to the
inputs and outputs of the safety module. The connections are made intuitively using the
mouse, and the editor prevents impermissible connections (e.g., between certain outputs).
In addition, the software provides a safe parameter editor, which can be used to configure
each input and output of the PSR-TRISAFE-S safety module.
A special online mode supports a detailed
function test
of the safety logic executed in the
PSR-TRISAFE-S safety module. Current signal values can be read from the
PSR-TRISAFE-S safety module, transmitted to the configuration software, and displayed
there "live" in the connection editor.
For more detailed information about the configuration software, please refer to the software
description in Section 4.
Secure communication
Communication between the PSR-TRISAFE-S safety module and the configuration
software is via a USB interface.
A special security protocol enables secure data transmission via the USB interface.
There is communication between the two components in both directions:
–
PC
→
safety module: The configuration data and device parameters are downloaded
from the configuration PC to the safety module. Configuration data refers to the
application logic, which was created using SAFECONF.
The configuration can also be downloaded using the plug-in IFS-CONFSTICK. Please
refer to "Downloading the configuration from SAFECONF" on page 5-4 and
"Downloading the configuration using the IFS-CONFSTICK" on page 5-7.
–
Safety module
→
PC: For diagnostic purposes, online values can be read from the
PSR-TRISAFE-S safety module via the USB interface and displayed "live" in the
software. For more detailed information, please refer to "Function test" on page 5-10.
Summary of Contents for 2986229
Page 2: ......
Page 32: ...PSR TRISAFE S 2 16 PHOENIX CONTACT 103503_en_03...
Page 50: ...PSR TRISAFE S 3 18 PHOENIX CONTACT 103503_en_03...
Page 74: ...PSR TRISAFE S 4 24 PHOENIX CONTACT 103503_en_03...
Page 88: ...PSR TRISAFE S 5 14 PHOENIX CONTACT 103503_en_03...
Page 90: ...PSR TRISAFE S 6 2 PHOENIX CONTACT 103503_en_03...
Page 96: ...PSR TRISAFE S 7 6 PHOENIX CONTACT 103503_en_03...