PSI-MODEM-SHDSL/ETH
38
PHOENIX CONTACT
104273_en_01
4.2
Connections and LEDs
Connection terminal blocks (COMBICON)
1
24V
Supply 24 V
2
0V
Supply 0 V
3
DO
Switching output, digital (24 V, open)
4
DIO
Switching output, digital (24 V, open)
5/6
A (a)/(b)
DSL port A (wire pair 1)
7/8
B (a)/(b)
DSL port B (wire pair 2)
Interfaces
18
USB
Mini-USB, type B, 5-pos., interface for configuration and diagnostics
19
RJ45
Ethernet interface (TP port)
Status and diagnostic indicators
9
VCC
(green) Supply voltage
On
Supply voltage OK
Flashing (1 Hz)
Supply via USB (only for configuration)
Flashing (2 Hz)
Error during boot process (ERR also flashes)
10
DIAG
(yellow) Diagnostics
Off
No serious errors
Flashing (1 Hz)
(Duration: 20 seconds after booting)
Device is in default settings
Flashing (2 Hz)
Remote access from another device (data transmission
during remote configuration, remote diagnostics, firm-
ware update)
On
Serious error occurred -
read out of diagnostic data is recommended
11
ACT
(yellow) Ethernet interface
On
Data traffic on Ethernet interface
12
LINK
(green) Ethernet interface
Off
No connection
On
Connection established
13
ERR
(red)
Error
Flashing (2 Hz)
Error during boot process (VCC also flashes)
On
Telegram error/installation error
14
LINK
(green) DSL ports
16
Off
DSL port not active
Off (pulsating)
(Flashing every 3 s) DSL port is searching for link device
Flashing (1 Hz)
Link partner found
Flashing (2 Hz)
Initializing connection
Flashing (4 Hz)
ERR ON / STAT DSL OFF = Installation error: e.g., line
structure configured, but 4-wire point-to-point connec-
tion implemented
On
Connection established
15
STAT
(yellow) DSL ports
17
Off
No connection established
Off (pulsating)
(Lights up every 3 s) Connection quality adequate
On (pulsating)
(Goes out every 3 s) Connection quality good
On
Link quality very good
PSI-MODEM-SHDSL/ETH
Ord.-No. 23 13 643
VCC
DIAG
ACT
LINK
ERR
LINK
STAT
LINK
STAT
14
1
5
16
17
18
1
0
11
12
13
7
8
9
DSL
A
DSL
B
ETH
ETH
USB
1
2 3 4
5
6
19
Summary of Contents for 2313643
Page 16: ...PSI MODEM SHDSL ETH TC ETH EXTENDER 16 PHOENIX CONTACT 104273_en_01...
Page 20: ...PSI MODEM SHDSL ETH TC ETH EXTENDER 20 PHOENIX CONTACT 104273_en_01...
Page 50: ...PSI MODEM SHDSL ETH 50 PHOENIX CONTACT 104273_en_01...
Page 78: ...PSI MODEM SHDSL ETH TC ETH EXTENDER 78 PHOENIX CONTACT 104273_en_01...
Page 94: ...PSI MODEM SHDSL ETH TC ETH EXTENDER 94 PHOENIX CONTACT 104273_en_01...