Description of the technology
104273_en_01
PHOENIX CONTACT
23
Increasing noise immunity
Noise immunity can be increased by reducing the data rate. There are two options in the
configuration software:
–
Switch the data rate detection to "manual" and reduce the data rate.
–
Leave the data rate detection set to "automatic" and change the noise immunity with the
slider.
Control with the slider is especially suitable for longer paths. With slip rings, the manual set-
ting is better.
Figure 3-3
PSI-CONF: slider
Improved diagnostics
Both the local diagnostic data as well as the diagnostic data of the remote device are avail-
able to you.
Figure 3-4
PSI-CONF: path status
In the case of an event message, possible reasons and solutions are displayed when you
double-click the corresponding symbol in diagnostics.
Figure 3-5
PSI-CONF: diagnostic function