BL2 PPC 1201-4/…
12/24
PHOENIX CONTACT
4031_en_C
3.2.1
Power connection
A two-wire removable connector is provided for providing power to the BL2 PPC 1201-4/….
Figure 3
-
5
Power connector
Connect a power source to the included power connector. This connector supports wire
sizes from 0.2 to 2.5 mm² (24 to 12 AWG). Torque the wire-retaining screws in the
connector to 0.5 Nm (4.4 lb
f
-in.). Secure the connector to the BL2 PPC 1201-4/… chassis.
Table 3
-
2
Power connector
Pin No.
Description
–
0 V DC
+
24 V DC ±20%
CO
M 1
—
+
HD
MI
D C
-IN 9
~30V
+
—
NOTE:
To ensure safe operation, use safety extra-low voltage (SELV) according to DIN EN 61131
as supply voltage.
This device is protection class I item of equipment.
UEFI is set to boot on power, allowing the system to boot as soon as the power plug is
installed. This can be changed in the UEFI.