background image

Electro Magnetic Compatibility (EMC)

This equipment complies with European rules for EMC according to
EN55013, EN55020 and EN50082-1.

Operation is subject to the following two conditions:

1

This device may not cause harmful interference.

2

This device must accept any interference received, including interference
that may cause undesired operation.

The equipment conforms with the EMC directive and low-voltage
directive.

This device complies to FCC rules under test conditions that included
use of system cables and connectors between system components. If you
have any problems, contact your dealer.

Warnings

Any unauthorized modification to this equipment may cause violation of
the FCC rules resulting in the revocation of the authorization to operate
the equipment.

To prevent fire or shock hazard, do not expose this accessory to rain or
moisture.

The exclamation mark within a triangle is intended to alert the
user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the
appliance.

2

Summary of Contents for VSS7902/00T

Page 1: ...is device complies to FCC rules under test conditions that included use of system cables and connectors between system components If you have any problems contact your dealer Warnings Any unauthorized modification to this equipment may cause violation of the FCC rules resulting in the revocation of the authorization to operate the equipment To prevent fire or shock hazard do not expose this access...

Page 2: ... PIR detector Location of the PIR Installation of the PIR PIR settings Walk test LED Pulse counter System cable Action output Alarm input Settings 13 Designating the box CAMERA switch Box number Tamper switch active Last in line switch Double addressing error English g Read these instructions before putting your system in operation English 3 g ...

Page 3: ... power adapter The following items are included in this kit 1 Alarm action box 1 System cable 5m 15ft 1 User manual 1 PIR unit for version with PIR 1 Cable 50 cm for interconnection between alarm action box and PIR for version with PIR Colour Observation Monitor CL 66610005_005b AI 4 6 6 7 2 talk action menu _ next auto view Colour Observation system Colour Observation Monitor 4 4 4 4 4 4 5 3 1 R ...

Page 4: ... the security system All kinds of detectors having a N O or N C contact are supported for example infrared detectors smoke detectors magnetic door window contacts When a detector triggers the alarm action box the system monitor automatically switches to the camera input the alarm action box is designated to The system monitor produces an alarm and activates its alarm contact There are two versions...

Page 5: ...power is switched on Use the power switch to switch off Operating the power save key is not sufficient If switching off is impracticable use the auto install option of the system monitor s install menu Mounting the box 1 Loosen the screw holding the cover and remove the cover 2 Remove the circuit board 1 3 Fasten the bottom plate of the box with two screws CL 66610005_501 AI CL 66610005_502 AI CL ...

Page 6: ...of the PIR The position of the PIR determines its view Select a location where an eventual burglar is most likely to be detected Place the sensor at a height of 2 2 m to accomplish the largest field of view see figure below Sensor range lens position 0 Side view Top view Be aware of the following before mounting the PIR Avoid a location of the PIR near to radiators heating cooling ducts or air con...

Page 7: ...ing the fixation screw 1 Warning Never touch the face of the PYRO sensor refer to lay out drawing next page 3 Knock out the desired mounting holes 1 and wiring holes 2 in the bottom plate 4 Thread the wires through the knocked out wiring hole s 5 Fasten the bottom plate with two screws using the mounting holes 6 Fit the circuit board CL 76610006_002 AI 3 1 2 CL 76610006_003 AI 1 1 2 g 8 ...

Page 8: ... m 1 5 m 10 m 8 5 m 8 m 7 Make the interconnections between the PIR and the alarm action box with the cable supplied see figure below 1 Terminal block for interconnection with alarm action box 2 Lens position sensor range adjustment 3 Jumper walk test LED activated deactivated 4 Tamper switch 5 PYRO sensor 6 Jumper 1 2 or 3 pulse count 7 Locking latch 8 Terminal block in alarm action box CL 766100...

Page 9: ...e previous figure for the location of the jumpers Walk test LED jumper installed Walk test LED is activated When the PIR sensor is triggered the LED will light jumper not installed Walk test LED is deactivated Pulse counter Set this jumper to select the number of times the sensor must be triggered 1 2 or 3 times before an alarm is generated The following jumper settings are possible Remark The PIR...

Page 10: ...he figure below If the cable length between monitor and camera exeeds 200m 600ft after an accessory is inserted in the line a mains power adapter should be used to power the camera see accessories Caution The plugs used for the observation system have the same dimensions as standard telephone plugs Never connect the security system with telephone equipment The two sockets for the system cable are ...

Page 11: ...connected 1 System cable input 2 System cable output 3 Switches 1 2 3 4 Rotary switch designates the box to a camera input 5 Tamper switch 6 Terminal block for optional Passive Infra Red detector 6 CL 66610005_505 AI 1 2 3 7 6 8 9 4 0 1 2 3 5 4 5 2 1 3 CAMERA 1 BOX TAMPER N LAST ON OFF 2 Y OFF _ NC PIR g 12 ...

Page 12: ...de switches have the following functions Switch Off On Description 1 BOX 1 2 number of accessories 2 TAMPER TAMPER OFF tamper switch override 3 LAST N Y last accessory box Designating the box CAMERA switch Designating a box to a camera input means that system monitor associates the box with a certain camera input the designated input although it is physically connected to another This causes the s...

Page 13: ...e action relay when the action button on the system monitor is pressed Remark The maximum amount of accessories on one camera input is two intercom boxes and two alarm action boxes CL 66610005_510b AI 2 1 2 7 6 8 9 4 0 1 2 3 5 CAMERA 7 6 8 9 4 0 1 2 3 5 7 6 8 9 4 0 1 2 3 5 CAMERA CAMERA talk action menu _ next auto view Colour Observation system R A E N R A F 1 R A E N R A F g 14 ...

Page 14: ...ignated to the camera input set by CAMERA Tamper switch active On the circuit board a tamper switch secures the box When opening the box this switch triggers an alarm on the monitor To suppress a continuous alarm message while servicing the system the tamper switch override is set in the OFF position Caution Don t forget to reactivate the tamper switch by switching the override to the TAMPER posit...

Page 15: ...cessories in any camera line will be functioning If the system monitor detects two boxes with the same designation and box number it shows the following error message DOUBLE ADDRESSING Accessory name INPUT X X Change from one alarm action box the BOX switch or the CAMERA switch Explanation INPUT X X the physical camera input numbers to which the double addressed boxes are connected g 16 ...

Page 16: ...put System connectors RJ11E modular telephone connectors System cable 4 wire dual twisted pair telephone cable PIR angle of sight horizontal 110 vertical 20 Dimensions without PIR 119 x 77 x 40 mm Ambient conditions ammonia resistant Temperature operating 10 45 C storage 25 70 C Humidity operating 20 90 RH storage 20 99 RH Specifications may change without notice 171 ...

Reviews: