background image

Electro Magnetic Compatibility (EMC)

This equipment complies with European rules for EMC according to
EN55013, EN55020 and EN50082-1.

Operation is subject to the following two conditions:

1

This device may not cause harmful interference.

2

This device must accept any interference received, including interference
that may cause undesired operation.

The equipment conforms with the EMC directive and low-voltage
directive.

This device complies to FCC rules under test conditions that included
use of system cables and connectors between system components. If you
have any problems, contact your dealer.

Warnings

Any unauthorized modification to this equipment may cause violation of
the FCC rules resulting in the revocation of the authorization to operate
the equipment.

To prevent fire or shock hazard, do not expose this accessory to rain or
moisture.

The exclamation mark within a triangle is intended to alert the
user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the
appliance.

2

Summary of Contents for VSS7901/00T

Page 1: ...is device complies to FCC rules under test conditions that included use of system cables and connectors between system components If you have any problems contact your dealer Warnings Any unauthorized modification to this equipment may cause violation of the FCC rules resulting in the revocation of the authorization to operate the equipment To prevent fire or shock hazard do not expose this access...

Page 2: ...box System cable Doorbell output External power supply Volume of the loudspeaker Settings 9 Designating the box CAMERA switch Box number Tamper switch active Double addressing error Operation 11 English g Read these instructions before putting your system in operation English 3 g ...

Page 3: ...erface box 6 System cameras 7 Non system camera s CVBS 8 Mains power adapter The following items are included in this kit 1 Intercom box 1 System cable 5m 15ft 1 User manual Colour Observation Monitor CL 66610005_005a AI 4 6 6 7 2 talk action menu _ next auto view Colour Observation system Colour Observation Monitor 4 4 4 4 4 4 5 8 3 1 R A E N R A F R A E N R A F g 4 ...

Page 4: ...ws you and the person near the intercom box to talk to one another Installation Remark When the system configuration is altered the system monitor needs to check and memorise the configuration of the cameras and accessories connected to its inputs This is done automatically when the power is switched on Use the power switch to switch off only operating the power save key is not sufficient If switc...

Page 5: ...f the box with two screws 4 Fit the circuit board 5 Now make the connections as described below 6 IMPORTANT Adjust the settings of the circuit board switches to configure the box according to your system See section settings 7 Fit the cover and secure the screw holding it CL 66610005_509 AI CL 66610005_502 AI CL 66610005_504 AI g 6 ...

Page 6: ... the figure below If the cable length between monitor and camera exeeds 200m 600ft after an accessory is inserted in the line a mains power adapter should be used to power the camera see accessories Caution The plugs used for the observation system have the same dimensions as standard telephone plugs Never connect the security system with telephone equipment The two sockets for the system cable ar...

Page 7: ...amper switch 6 Volume preset External power supply If at maximum volume setting the loudspeaker volume remains low then connect an external power supply 24VDC 0 5A as shown in the figure above 7 This is advised when the intercom box is connected to the system monitor through a long cable 7 CL 66610005_508 AI 7 6 8 9 4 0 1 2 3 5 5 6 1 2 4 24VDC CAMERA 4 1 2 3 3 1 BOX BELL BELL 24V GND TAMPER N LAST...

Page 8: ...erride 3 LAST N Y last accessory box Designating the box CAMERA switch Designating a box to a camera input means that system monitor associates the box with a certain camera input the designated input although it is physically connected to another This causes the system monitor to switch to the camera connected to that input when for example an alarm is triggered or the doorbell button pressed Thi...

Page 9: ...nated to the camera input set by CAMERA Tamper switch active On the circuit board a tamper switch secures the box When opening the box this switch triggers an alarm on the monitor To suppress a continuous alarm message while servicing the system the tamper switch override is set in the TAMPER OFF position Caution Don t forget to reactivate the tamper switch by switching the override to the TAMPER ...

Page 10: ...unds The monitor system slave switches to the camera input the intercom is designated to The automatic camera sequence stops If you don t react within 3 minutes by pushing any button then the monitor returns to its previous status for example the automatic camera sequence continues The system monitor reproduces the sound received from the intercom box plus that of the camera the system switched to...

Page 11: ... ratings doorbell relay 30V 1A AC DC System connectors RJ11E modular telephone connectors System cable 4 wire dual twisted pair telephone cable Dimensions 119 x 77 x 40mm Ambient conditions ammonia resistant temperature operating 10 45 C storage 25 70 C humidity operating 20 90 RH storage 20 99 RH Specifications may change without notice 111 ...

Reviews: