Tips for filter
element replacement
Standby indicator
Temperature /
timing display
Operation mode selection
Operation
UVCA110/210
Operation instruction
Type Desc
Voltage
UVCA110
UVCA210
254 nm
Lamp
Holder
G5
Frequency
50-60Hz
220-240V~
4x TUV 11W
4x TUV 16W
Lamp
UV-C
Wavelength
Power
53W
90W
Only use PHILIPS brand TUV lamp
TUV lamp type:
928002204019 TUV 11W
928002004019 TUV 16W
TUV lamp lifetime:9000h
Size
LxWxH (cm)
Our UV-C Products are not meant to be used in applications or activities which may cause and/or lead to death, personal
injury and/or damage to the environment.
This UV-C product is intended to be used for the disinfection of Indoor air.
This UV-C product is not approved and / or certified as a medical device.
The back cover must be closed properly before disinfection, otherwise the UV-C lamp won’t work. There should be no light
leakage at the air inlet on the side of the body. If there is, please check whether the filter is installed correctly.
Signify will not be responsible for any accidents/injuries caused by exposure to UV-C light.
Please contact manufacturer or its maintenance department and other similar professionals for repair. When the product is
working normally, the UV-C irradiance at 200mm from the product is <1mW/m . If the power cord is damaged, it must be
replaced with a dedicated cord or with a dedicated component purchased from its manufacturer or maintenance
department.
UV-C Exposed luminaire parts (other than metal parts), like Lamp holder, end cap etc. might change color after a certain
period of usage due to the UV-C light property.
UV-C light emitted from UV-C lamp is much “stronger” than normal sunlight and can cause a severe sunburn-like reaction to
your skin, and similarly, could damage the retina of your eye, if exposed. This appliance is not intended for use by persons
(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
In case of accidental breakage of the lamp tube, it should be ventilated for 30 minutes first. Please remove the debris with
gloves, put it in a sealed plastic bag and take it to a local waste disposal site for safe disposal.
•
•
•
•
Don't put into water.
Don't splash water on the filter.
Don't put sundries into the air outlet.
Don't use on the ground with water or under the wet environment.
•
Power off during maintenance or cleaning.
•
External: the body can be cleaned with a wet towel. Strong solvents or detergents are not recommended. But
neutral mild cleaners are recommended
,
no residue after cleaning.
•
Interior: clean the interior metal walls with ethanol (reagent grade) and soft towel. Be careful not to spray or
apply chemicals directly on the UV -C lamp tube. This may damage the product.
•
Please maintain in strict accordance with the above requirements.
Maintenance
•
•
•
Filter/Lamp/other relevant parts replacement
Ensure the filter is properly installed during maintenance
or switch on, otherwise it will cause UV-C
leakage.
Only those who have received instruction training can replace the other relevant parts. Please contact
Signify dealer or the designated after-sales service.
Please Shut off the power supply and unplug product before changing the lamp or filter! Please ensure
to put on gloves when installing the luminaire or replacing the lamp.
switch/function botton
sensor receiver
filter
back cover
power cord
UV-C chamber
power cord socket
air inlet
air outlet
display transparent board
H
W
L
●
Power on
Plug the power cord into the power socket, plug the power cord socket into the electric supply. When the standby
indicator lights up, long press the button for 2 seconds to turn on the machine, the product starts running.
●
Mode selection
Turn the function button to select the product operation mode, including Speedy and Medium speed and Low
speed.
●
Timing selection
Press the function button till letter "h" lights up and flash, and then turn the button to select operating time from 1
to 16 hours. If need to be out of timing selection, please press selection button exist.
●
Temperature detection
When the machine is turned on, the temperature of current indoor environment is displayed digitally.
●
Tips for filter replacement
When the operation time of machine reaches the lifetime of filter (9000h) , the replacement indicator lights
“ ”up to prompt the use to replace the filter. When the machine running time to reach the lifetime of the
UV-C lamp (9000h), the display number will show “E8” lights up to prompt the use to replace the UV-C lamp . After
changing the filter and UV-C lamps , press the selection button for 15 seconds, the machine will time again.
●
Troubleshooting of sterilizing UV-C chamber
When the sterilizing UV-C chamber fails to be installed , the display number will read 'EE" to prompt the use to
reinstall or replace the UV-C chamber.
WARNING UV-C
emitted from this product
(
inside UV
-
Cchamber
).
Avoid eye and skin exposure to unshielded product
.
Follow installa
on instructions and user manual.
UV-C RISK GROUP 3
Application Considerations
2
u
v-c
PHILIPS and the PHILIPS shield emblem are registered trademarks of koninklijke PHILIPS N.V.
2F, Building 1, No. 2555 Hechuan Road,
Minhang District, Shanghai City, P.R.China
Signify Luminaires(Shanghai)Co., Ltd
Postal code: 201101
5.4
7.3
23.5x23.5x56
28x28x70
•
Recommend to clean every six months.
•
Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation.
UV-C radiation may, even in little doses, cause harm to the eyes and skin.
•
Appliances that are obviously damaged must not be operated.
•
Read the maintenance instructions before opening the appliance.