background image

Summary of Contents for SL NITRO 510

Page 1: ......

Page 2: ...t dans ce manuel est pour information seulement et est sujet à changements sans préavis La compagnie Showline n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s il vous plait contacter le bureau de Showline le plus proche Note Information contained in th...

Page 3: ...ment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel e The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition f Do not use this equipment for other than intended use g Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a main circuit breake...

Page 4: ...cting to the DMX512 Network 9 Mounting Luminaire 10 Connecting Mounting Multiple Luminaires 10 Connecting Luminaires Top to Bottom 11 Connecting Luminaires Side to Side 12 Mounting SL NITRO 510 LED STROBE Luminaire with Other Luminaires 12 Connecting Combined Luminaires Top to Bottom 13 Connecting Combined Luminaires Side to Side 15 OPERATION AND PROGRAMMING LCD Display and Menu System 16 LCD Disp...

Page 5: ...DMX Timing Detail 30 SL NITRO 510 LED STROBE Luminaire RDM Parameter IDs 31 CLEANING AND CARE Special Cleaning and Care Instructions 34 Front Lens Cleaning 34 Service and Maintenance 34 TECHNICAL SPECIFICATIONS SL NITRO 510 LED STROBE Luminaire Operational Specifications 35 SL NITRO 510 LED STROBE Luminaire Dimensions 35 ...

Page 6: ... M12 x 25 2 Ea Flat Washer 2 Ea Lock Washer 2 Ea Nut M12 Luminaire Connecting Front Pin 1 each for joining luminaires end to end Part Number Description PC1BE SL NITRO 510 LED STROBE Luminaire AC Power Input Cable 39 inches 1 meter Powercon with Bare End Note user supplies and installs own AC input connector PC1GP SL NITRO 510 LED STROBE Luminaire AC Power Input Cable 39 inches 1 meter Powercon wi...

Page 7: ...minaire Components Major Luminaire Components Figure 2 SL NITRO 510 LED STROBE Luminaire Components Back of Fixture DMX512 AC Input Luminaire Mount x2 RDM Input Front of Fixture DMX512 AC Output RDM Output High Intensity White LED Array x1 350 Luminaire Mount Lock x2 Quick Connect Locking Pin x2 LCD Display Menu System refer to LCD Display Menu System on page 6 for additional information ...

Page 8: ...and Menu System on page 16 Home menu settings Edit a Preset Edit a Chase DMX512 Addressing Return to Main Screen LEFT Arrow Button UP Arrow Button CHECK MARK Accept Button DOWN Arrow Button RIGHT Arrow Button LCD Display NOTE Menu rotates with orientation of luminaire and menu buttons are always in the same position with rotation of menu To rotate menu 180 degrees from current orientation press an...

Page 9: ...se figures are based on the Maximum Allowable Input Current of 20 Amps and the maximum power supply limit of 360 Watts Do not overload circuits IMPORTANT AC POWER CONNECTION NOTES a When using the daisy chain connection method ONLY connect SL NITRO 510 LED STROBE Luminaires to AC Output Connection of SL NITRO 510 LED STROBE Luminaires DO NOT CONNECT OTHER TYPES OF LUMINAIRES OR DEVICES b Use only ...

Page 10: ...BE Luminaires to AC Power If the unit is supplied with an AC input cable without an input connector installed The input connector is a user supplied accessory Table 2 on page 8 describes how to connect power to your SL NITRO 510 LED STROBE Luminaire Field wiring of the SL NITRO 510 LED STROBE Luminaire is straight forward A total of 3 wires conductors is supplied from the unit The following wiring...

Page 11: ...the other DMX connector on the first unit to a DMX connector on the next SL NITRO 510 LED STROBE Luminaire or DMX512 device to be controlled Figure 5 SL NITRO 510 LED STROBE Luminaire DMX512 Input Output Connections Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page 1 For SL NITRO 510 LED STROBE Luminaire DMX Mapping refer to DMX CONTROL on ...

Page 12: ...together while retaining perfect pixel pitch Units may be connected in top to bottom or side by side to allow for a wide range of configurations In addition they may be connected together with the SL BAR 520 RGBW LED luminaire SAFETY CABLE Is sold separately and recommended for all hanging installation and may be required by national and local codes Use safety cable anchor points for safety cable ...

Page 13: ...nected fixtures Each fixture must use an approved safety cable attached to a fixed object Up to twenty SL NITRO 510 LED STROBE Luminaires may be supported when connected using the Quick Connect system When connecting units together ensure all Quick Connect pins are in the engaged position Side View Step 1 Move locking mechanism handle so locking pin clears locking mechanism Step 2 Lock Locking Mec...

Page 14: ...Each fixture must use an approved safety cable attached to a fixed object 6 Mounting SL NITRO 510 LED STROBE Luminaire with Other Luminaires The SL NITRO 510 LED STROBE Luminaire and SL BAR 520 LED Luminaire are designed to be connected together top to bottom and or end to end using the same connecting hardware The pixels of the SL BAR 520 LED Luminaire and the zones of the SL NITRO 510 LED STROBE...

Page 15: ...ee side to side pins installed refer to Figure 11 and Connecting Luminaires Side to Side on page 12 Figure 11 SL NITRO 510 LED STROBE Luminaires Connections When two SL NITRO 510 LED STROBE Luminaires are combined with a SL BAR 520 there is no top to bottom connection available in the center When a SL BAR 520 unit is mounted below the two SL NITRO 510 LED STROBE Luminaires the top to bottom connec...

Page 16: ...her under Bolt Head Bolt through both SL NITRO 510 LED STROBE Luminaire brackets Lock Washer and then Hex Nut Hand tighten WARNING Your structure must be capable of properly supporting the weight of multiple connected fixtures Each fixture must use an approved safety cable attached to a fixed object Up to ten luminaire rows may be supported when connected using the Quick Connect system Bolt Flat W...

Page 17: ...indicated in Figure 9 The three side to side pins must be installed per luminaire All three pins are used to connect luminaires together linearly Each fixture must be mounted using its own mount ing hardware The side to side pins are only to align the luminaires and do not provide hanging support Figure 12 shows an example of connecting luminaires side by side Figure 12 Connecting Combined Luminai...

Page 18: ... 510 LED STROBE Luminaire Main Menu Options on page 17 Upon power up the LCD will display the main screen showing the product type name If DMX is enabled the programmed address will appear after power up 2 LCD Display and Menu System Operation The LCD Display Menu system consists of several categories Use the Menu Buttons to access and make changes to the menu items When the desired menu item is r...

Page 19: ...ws will have no effect See Settings Security on page 18 Depending on the DMX map set assigned the DMX menu different parameters will be available See DMX CONTROL on page 24 for additional information Step 4 Once all values are adjusted as desired press the Check Mark button to save the preset Step 5 The Save Preset Menu option will appear Use the left and right arrow buttons to select the preset n...

Page 20: ...l presets and color filters Step 3 Use the Up and Down keys to scroll through the output parameters Once a parameter is selected use the left and right arrow buttons to make adjustments Notes If security features are enabled the Up and Down arrows will have no effect See Settings Security on page 18 Depending on the DMX map set assigned the DMX menu different parameters will be available See DMX C...

Page 21: ...n finished press the Check button to exit the menu level The adjustable parameters are described in Table 7 Table 4 Security Lock Levels Lock Level Menu Functions Affected Level 1 Edit Presets Edit Chases and Settings Menu Level 2 Settings Menu Level 3 All Table 5 PIN Level Parameters Parameter Description Enter Pass PIN Enter a PIN code matching the level codes assigned in the Settings Security m...

Page 22: ... disabled To assign fixture power up security refer to see Settings Security on page 18 for more information Password PassPIN The Password menu item will display an Enter PassPIN dialog box Use the Up Down Left Right buttons to enter a PIN code matching the codes assigned in the Settings Security menu to toggle the current security level Load Factory No no action Yes restore to factory default men...

Page 23: ...rt address for the fixture by pressing the Quick Select button on the top of the menu system as shown right The current DMX start address will be display in large digits To edit the DMX start address Step 1 Press the Check Mark button to begin the DMX start address editing The last digit will change to a blue color Step 2 Use the UP and Down arrows to change the value of the currently selected dig...

Page 24: ...o select one of four dimming curves Linear Curve PL_Curve S_Curve Square Curve Figure 14 SL NITRO 510 LED STROBE Luminaire Dimmer Curves PL Curve follows the dimming curve of Philips Selecon PL series LED luminaries DMX Value Lumen Output 0 Linear Curve DMX Value Lumen Output 0 S_Curve DMX Value Lumen Output 0 Square Curve DMX Value Lumen Output 0 PL_Curve ...

Page 25: ...r Mode through the unit s menu system Step 2 Set all other connected units to Slave Mode Step 3 The master unit can be controlled via DMX512 RDM or through standalone operation self contained network utilizing on board effects The slave units will mimic the master unit s operation in all cases Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on pa...

Page 26: ...s in Single Channel DMX512 mode as set by the luminaire s menu system 2 Three Channel Control Mode Table 12 provides DMX channel mapping of all DMX512 control values when the SL NITRO 510 LED STROBE Luminaire is in Three Channel DMX512 mode as set by the luminaire s menu system Table 11 DMX Channel Mapping Single Channel Mode DMX Channel Parameter Range DMX Range Default recom mended console defau...

Page 27: ...s 0 255 0 100 0 Controls strobe operation as follows No Effect DMX 0 5 default Ramp Up DMX 6 42 Ramp Down DMX 43 85 Ramp up down DMX 86 128 Random DMX 129 171 Top row only DMX 172 173 Bottom row only DMX 174 175 Left zone only DMX 176 178 Center zone only DMX 179 180 Right zone only DMX 181 182 Checker pattern A DMX 183 184 Checker pattern B DMX 185 186 Random zones DMX 187 214 Circle zone chase C...

Page 28: ... hold value for at least 5 seconds then turn to 0 Set control channel value to 0 without any scaling Default Setting on Console DMX 0 4 Dimming Curve_linear DMX 30 34 Dimming Curve_Square DMX 35 39 Dimming Curve_S Curve DMX 40 44 Dimming Curve_PL Curve DMX 45 49 Fan_Auto DMX 80 84 Fan_Off DMX 85 89 Not Used DMX 105 250 Reserved for future use 5 Strobe Duration 0 255 0 100 0 Controls strobe duratio...

Page 29: ...9 Dimming Curve_S Curve DMX 40 44 Dimming Curve_PL Curve DMX 45 49 Fan_Auto DMX 80 84 Fan_Off DMX 85 89 The following is only for Zones Mapping protocol The following is instantly active and does not require the 5 second hold Combined zone control all zones follow zone 1 setting DMX 100 104 Not Used DMX 105 250 Reserved for future use 5 Zone 1 Intensity 0 255 0 100 0 8 bit control of Zone 1 intens...

Page 30: ...ol of Zone 5 intensity 0 to 255 full 18 Zone 5 Strobe Duration 0 255 0 100 0 Controls strobe duration for Zone 5 Refer to Strobe Duration DMX Timing Detail on page 30 19 Zone 5 Strobe Rate 0 255 0 100 0 Controls strobe rate for Zone 5 Refer to Strobe Rate DMX Timing Detail on page 29 20 Zone 6 Intensity 0 255 0 100 0 8 bit control of Zone 6 intensity 0 to 255 full 21 Zone 6 Strobe Duration 0 255 0...

Page 31: ... Sh wline 6 Strobe Rate DMX Timing Detail The chart below describes the Strobe Rate DMX parameters of the SL NITRO 510 LED STROBE Luminaire Note Continuous ON Mode illuminates all LEDs without strobing This feature is activated when Strobe Rate and Strobe Duration are both set to DMX value 255 ...

Page 32: ...7 20 8 656 80 2624 140 55 4592 200 6560 21 689 81 2657 141 4625 201 79 6593 22 722 82 32 2690 142 4658 202 6626 23 9 754 83 2722 143 56 4690 203 6658 24 787 84 33 2755 144 4723 204 80 6691 25 10 820 85 2788 145 57 4756 205 6724 26 853 86 2821 146 4789 206 81 6757 27 886 87 34 2854 147 4822 207 6790 28 11 918 88 2886 148 58 4854 208 6822 29 951 89 35 2919 149 4887 209 82 6855 30 984 90 2952 150 59 ...

Page 33: ... Category 0x1138 Philips Entertain Lighting Asia SL NITRO 510 0x1180 Table 17 SL NITRO 510 LED STROBE Luminaire RDM UID UID MSB of ESTA 50H LSB of ESTA 41H 1st of Unique Seq 2nd of Unique Seq 3rd of Unique Seq 4th of Unique Seq Table 18 SL NITRO 510 LED STROBE Luminaire RDM Parameters IDs Get Allowed Set Allowed RDM Parameter IDs Value Comment Implemented Category Network Management DISC_UNIQUE_BR...

Page 34: ...FAULT_SLOT_VALUE 0x0122 Category Sensors 0x02xx SENSOR_DEFINITION 0x0200 SENSOR_VALUE 0x0201 RECORD_SENSORS 0x0202 Category Dimmer Settings 0x03xx FUTURE USE Category Power Lamp Settings 0x04xx DEVICE_HOURS 0x0400 LAMP_HOURS 0x0401 LAMP_STRIKES 0x0402 LAMP_STATE 0x0403 LAMP_ON_MODE 0x0404 DEVICE_POWER_CYCLES 0x0405 Category Display Settings 0x05xx DISPLAY_INVERT 0x0500 DISPLAY_LEVEL 0x0501 Categor...

Page 35: ... Data Value 1 Data Value 2 Status ID Description 8100H 00H 00H ALL OK Table 20 SL NITRO 510 LED STROBE Luminaire RDM Manufacturer Specific PIDs for Root Device Get Allowed Set Allowed RDM Parameter IDs Type Length Unit Prefix Min Max Default Description Category Manufacturer Defined PIDs Range is 0x8000 0xffdf See ANSI E1 20 2010 Standard Table A 3 8A00H U8 1 None None 0 100 100 Dimmer 8AB2H U8 1 ...

Page 36: ...astic optics with anti reflection coatings If the lens is still dirty after using isopropyl alcohol for instance if fingerprints or oil is just redistributed and not cleaned off the optic then a mild soap and water solution can be used to gently wash the lens Repeat the cleaning with isopropyl alcohol to eliminate streaks and soap residue WARNING Under no circumstances should ammonia based cleaner...

Page 37: ...00V 1 50 Amps 240V Frequency 50 60Hz Control Protocols DMX512 1990 DMX512A RDM On Board Menu Ambient Temperature 20 to 40 Degrees C 4 to 104 Degrees F Humidity 5 95 Non condensing Cooling Forced Air Cooling Weight 15 4 lbs 7 kg Luminaire only no accessories Housing Die Cast Aluminium with Powder Coating Compliance cETLus marked North American models and CE Marked International models IP Rating IP2...