Beam Shutter Operation

CAUTION:  When adjusting the luminaire’s beam shutter, it is important to wear protective gloves.  The luminaire produces 
extreme heat and all surfaces could cause serious burns if touched.

Each LEKO LITE Luminaire is equipped with four 
independent shutters (as shown in Figure 6) to block 
or shape light as desired. After the luminaire is 
installed and positioned, move the shutters in or out 
as required.

Gobos

Each LEKO LITE Luminaire is capable of holding two 
gobo holders, each containing one "B" sized glass or 
steel gobo.  

To install or change a gobo:

1.

As shown in Figure 7, loosen, but do not 
remove, two retaining knobs that secure gobo 
access panel. Slide open gobo access panel.

2.

Install gobo into gobo holder in desired 
orientation.

3.

Slide gobo holder into luminaire gobo slot.

4.

Close gobo access door.  Make sure gobo 
holder handle fits inside one of two slots in 
gobo access panel.

5.

Hand tighten gobo access panel retaining 
knobs.

Maintenance & Cleaning

Lenses, reflector, gobos, lamps, etc. should only be 
cleaned with isopropyl alcohol and never with any 
ammonia-based product.  Also, cleaning should only 
be done with power completely removed from the 
luminaire and the luminaire cool to the touch.

Note:  For extremely dirty lenses, a mild soap/detergent and distilled water solution should be used prior to cleaning with 

Isopropyl Alcohol.  Always use a soft, lint free cloth after blowing away loose particulates with clean, oil-free air.

Strand Lighting Offices:

Strand Lighting - Dallas
10911 Petal Street
Dallas, TX 75238
Tel: +1 214-647-7880
Fax: +1 214-647-8030

Strand Lighting Asia Limited
Room 6-10,
20/F Delta House 3 On Yiu Street
Shatin, N.T. Hong Kong
Tel: + 852 2757 3033
Fax: + 852 2757 1767

Strand Selecon - Auckland
19-21 Kawana Street
Northcote, Auckland 0627
New Zealand
Tel: +64 9 481 0100
Fax: +64 9 481 0101

Strand Lighting - New York
267 5th Ave, 4th Floor
New York, NY 10016
Tel: +1 212-213-8219
Fax: +1 212-532-2593

Strand Lighting - Europe
Marssteden 152
Enschede 7547 TD
The Netherlands
Tel: +31 53 4500424
Fax: +31 53 4500425

For service and support, please contact your 
Authorized Strand Lighting Dealer or the nearest 
Strand Lighting office. For the office or dealer 
near you, please visit www.strandlighting.com.

Figure 6:  Beam Shutters 

Beam Shutters 

(4 Each)

Front View

See Detail A

Figure 7:  Gobo Holder & Access Panel

Retaining Knobs

(2 Each)

Gobo Access Panel

Detail A

Gobo

Area

Gobo Holder

 

User’s & Installation Guide

IMPORTANT!  Retain these instructions for future reference.  DO NOT DISCARD!

For use with the following models:

11430C, 15

o

 to 32

o

 Variable Beam Angle LEKO LITE Luminaire

11440C, 23

o

 to 50

o

 Variable Beam Angle LEKO LITE Luminaire

11500C, 5

o

 Fixed Beam Angle LEKO LITE Luminaire

11510C, 10

o

 Fixed Beam Angle LEKO LITE Luminaire

11520C, 19

o

 Fixed Beam Angle LEKO LITE Luminaire

11530C, 26

o

 Fixed Beam Angle LEKO LITE Luminaire

11540C, 36

o

 Fixed Beam Angle LEKO LITE Luminaire

11550C, 50

o

 Fixed Beam Angle LEKO LITE Luminaire

Manual Number: 02.8101.0001 A

LEKO LITE Luminaire User’s & Installation Guide

Summary of Contents for Leko Lite 11430C

Page 1: ... away loose particulates with clean oil free air Strand Lighting Offices Strand Lighting Dallas 10911 Petal Street Dallas TX 75238 Tel 1 214 647 7880 Fax 1 214 647 8030 Strand Lighting Asia Limited Room 6 10 20 F Delta House 3 On Yiu Street Shatin N T Hong Kong Tel 852 2757 3033 Fax 852 2757 1767 Strand Selecon Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax ...

Page 2: ...pecifies the minimum distance from the luminaire to a flammable surface The top figure is to a surface in the light beam and the bottom figure to a surface near the luminaire body Tmax specifies the maximum surface temperature for the luminaire body Ta specifies the maximum ambient operating temperature for the luminaire Luminaire operational voltage range Do not mount luminaire on or allow contac...

Page 3: ...e values marked on the luminaire Focus and Beam Angle Adjustments CAUTION When adjusting the luminaire s focus or beam distribution it is important to wear protective gloves The luminaire produces extreme heat and all surfaces could cause serious burns if touched Variable Beam Angle Models Before adjusting beam focus the luminaire s light field should be adjusted for optimum performance Peak Field...

Page 4: ...ety Cable 18147 5 inch Gel Frame Extender Center Clamp Mounting Hole Luminaire Yoke Assembly Luminaire Handle CAUTION Remove power and allow luminaire to cool before handling or servicing Focus and Beam Angle Adjustments CAUTION When adjusting the luminaire s focus or beam distribution it is important to wear protective gloves The luminaire produces extreme heat and all surfaces could cause seriou...

Reviews: