Front View
HUDSON
1
50C5 V002 200405
11
F
actory Mode
Indicator
---------->
F
actory Menu
Cursor can move on gray color area
AGING...
After
1
5 seconds,
bring up:
After
1
5 seconds,
bring up:
AGING...
After
1
5 seconds,
bring up:
----------
----------
repeatly
Connect Signal cable again
=
> go back to normal display
How to Access Aging Mode
Step
1
: Turn off LCD monitor, and disconnect Interface Cable betwe-
en Monitor and PC.
Step 2 :
[
Push
"
AUTO
" & "
OK
"
buttons at the same time and hold it
]
+
[
Press power
"
"
button untill comes out
"
AGING screen
"] =
>
then release all buttons.
Bring up:
150C5 LCD
1
5
Factory Mode & Aging Mode
How to enter Factory Mode
1
. Turn off the monitor.
2.
[
Push
"
AUTO
" & "
OK
"
buttons at the same time and hold it
]
+
[
Press power
"
"
button until comes out
"W
indows screen
"]
=
> then release all button, then press
, wait until the
OSD menu with Characters HUDSON
1
50C5 V002 200405
11
(below OSD menu) come on the Screen of the monitor
(see
F
ig. 2).
"
OK
"
button
BL
: Black level value
SUB- BRI
: Brightness value range( Min Max)
SUB- CON : Contrast value range( Min Mid Max )
SRGB- B
: Brightness of sRGB
SRGB- C
: Contrast of sRGB
Gain- m
: Minimum value of User Gain
Gain- M
: Maximum value of User Gain
AUTO- SUB : To do Auto color function when push Menu key in white
pattern
OSD TIMER: OSD time out control(sec)
IDX
: Limit current of inverter (CPT: 28) (LG:7)
Panel TYPE :PLS
reference section 2.9.6
SCALER
: Read/
W
rite scaler register
Panel
: HS (Hannstar panel)
CPT (CPT panel)
LG (LG. Philips panel)
7
HUDSON
1
50C5 V200 20040705
HS
1
.LG (7) 2. CPT (28) 3. HS (28) 4. QDI (28)
http://jdwxzlw.com/?fromuser=华盛维修