OEM Design Guide

Philips T5 VHO and HO Extreme Temperature Lamps and Ballasts

Summary of Contents for HCN2S5490CWL

Page 1: ...OEM Design Guide Philips T5VHO and HO Extreme Temperature Lamps and Ballasts ...

Page 2: ...rmal luminaire design and ballast lifetime 6 2 5 Luminaire design and EMI performance 7 2 6 Lamp holder cap 8 3 T5VHO and HO Extreme Temperature lamp specifications 8 3 1 Product offerings 8 3 2 Mechanical characteristics 8 3 3 T5VHO and HO ExtremeTemperature publication values 10 4 Ballast specifications for T5VHO and HO Extreme Temperature lamps 10 4 1 First start up 10 4 2 Ballast ordering elec...

Page 3: ...igh frequency electronic ballasts for maximum efficacy The Philips T5 Extreme Temperature range consists of the following types T5 VHO 95W Extreme Temperature 46 in T5 HO 54W Extreme Temperature 46 in They are available in the color temperatures 835 and 841 Features of PhilipsT5VHO and HO ExtremeTemperature ranges The lamps have the following characteristics A high initial lumen output of approxim...

Page 4: ...nts of local standards The maximum allowed temperature of the lamp cap is 248 F as given in IEC 61195 Double capped fluorescent lamps Safety specifications 2 2 3 Measuring the lamp cap for optimum lamp conditions In comparison with cold spot mercury lamps the relation between light output and cap temperature is less direct with amalgam lamps Over a broad temperature range the light output is at a ...

Page 5: ...is called the constant failure rate For a T5 VHO and HO ballast in normal operation this constant failure rate is approximately 50 000 hours at a fixed specified case temperature 194 F A temperature increase of approximately 18 F halves this lifetime thus 212 F gives 25 000 hrs while approximately 18 F lower doubles this figure 176 F gives 100 000 hrs 2 4 1 Thermal hints and tips There is an incre...

Page 6: ...ssible so affix the ballast directly to the luminaire The use of additional mounting plates or several junctions has a negative influence on EMC 2 Keep the lamp wiring short Avoid redundant wiring e g loops The so called hot wires should be the shortest and have the same symmetrical length for two lamp ballasts 3 Keep the mains wiring far away from lamp wiring Ensure that the mains wiring inside t...

Page 7: ... of the wiring with automatic probes inserted in the top of the lamp holder this operation is unfortunately no longer possible as the holes are used for the plastic insert of the Gx5 lamp holders The existing lamp holders for G5 capped lamps are suitable up to 250 volts which means that the applied voltage must be lower than 250 volts towards the ground As T5 lamps are especially designed for oper...

Page 8: ...a very broad temperature range The lumen output is above 90 of the maximum lumen output between 65 F and 170 F In table 3 1 the nominal values are given Lamp type Color Lamp Voltage V Discharge Current A Resistance Lamp power W Luminous flux lm T5 VHO 95W Extreme Temperature 835 841 123 800 mA 154 95 7200 T5 HO 54W Extreme Temperature 835 841 118 460 mA 255 54 5000 Lamp type Color Lamp Power W Lum...

Page 9: ...of the lamp Within 3 minutes the lamp will reach 80 of its final output In figure 3 2 a typical run up curve of a T5 Extreme Temperature lamp is shown Lumen maintenance The lumen maintenance of T5 Extreme Temperature lamps will be at 90 at 40 of rated average life See figure 3 3 32 F 50 F 68 F 86 F 104 F 122 F 140 F 158 F 176 F 32 F 50 F 68 F 86 F 104 F 122 F 140 F 158 F 176 F 0 C 10 C 20 C 30 C 4...

Page 10: ...arting Lamps Volts Method Number ANSI Watts Factor Amps Temp F C T5 VHO 1 277 PS JOP 2S95 G 116W 1 1 0 42 19 28 1 347 PS JOP 2S95 G 116W 1 1 0 35 19 28 1 480 PS JOP 2S95 G 116W 1 1 0 24 19 28 2 277 PS JOP 2S95 G 206W 1 0 0 74 19 28 2 347 PS JOP 2S95 G 206W 1 0 0 59 19 28 2 480 PS JOP 2S95 G 206W 1 0 0 43 19 28 T5 HO 1 120 PS ICN2S5490CWL 62W 1 0 0 52 20 29 1 277 PS ICN2S5490CWL 62W 1 0 0 23 20 29 ...

Page 11: ...nation with emergency situations 4 5 Switching cycle effects The rated average lamp life of T5 lamps is negatively affected when the switching frequency is higher than the IEC cycle 3 hrs cycle 2 hours and 45 minutes on 15 minutes off A 1 18 30mm B 1 70 43 2mm C 16 34 415mm D 16 70 424 4mm Figure 4 1 T5VHO andT5 HO 4 lamp case dimensions A 1 02 26mm B 1 18 30mm C 15 65 397 5mm D 16 34 415mm E 16 7...

Page 12: ...MP BALLAST BLUE YELLOW BLACK ORANGE BLACK WHITE RED HOT NEUTRAL LAMP One lamp operation Two lamp operation Advance ICN4S5490C2LSG T5VHO Ballast Four lamp operation 12 OEM Design Guide PhilipsT5VHO and HO ExtremeTemperature Lamps and Ballasts Notes Green terminal or ballast case must be grounded Mount lamp within 1 4 of grounded metal reflector MaxVoltage RED YELLOW leads 340Vrms Install in accorda...

Page 13: ...llast Advance ICN2S5490CWL T5VHO Ballast Four lamp operation Two lamp operation Advance HCN2S5490CWL T5VHO Ballast Two lamp operation OEM Design Guide PhilipsT5VHO and HO ExtremeTemperature Lamps and Ballasts 13 Notes Max Voltage RED YELLOW Leads 340Vrms Insulate unused leads for 600V Ballast case must be grounded Mount lamps within 1 4 of grounded metal reflector Notes Ballast case must be ground...

Page 14: ... Philips Lighting Company A Division of Philips Electronics North America Corporation All rights reserved Reproduction in whole or part is prohibited without the prior written consent of the copyright owner The information presented in this document does not form part of any quotation or contract is believed to be accurate and reliable and may be changed without notice No liability will be accepte...