1-4-1
H9720FIS
FUNCTION INDICATOR SYMBOLS
Note:
If a mechanical malfunction occurs, the power is turned off. When the power comes on again after that by
pressing [STANDBY-ON] button, an error message is displayed on the TV screen for 5 seconds.
TV screen
When reel or capstan mechanism is not functioning
correctly
When tape loading mechanism is not functioning cor-
rectly
When cassette loading mechanism is not functioning
correctly
When the drum is not working properly
P-ON Power safety detection
MODE
INDICATOR ACTIVE
When reel or capstan mechanism is not
functioning correctly
“EJECT R” is displayed on a TV screen. (Refer to Fig. 1.)
When tape loading mechanism is not func-
tioning correctly
“EJECT T” is displayed on a TV screen. (Refer to Fig. 2.)
When cassette loading mechanism is not
functioning correctly
“EJECT C” is displayed on a TV screen. (Refer to Fig. 3.)
When the drum is not working properly
“EJECT D” is displayed on a TV screen. (Refer to Fig. 4.)
P-ON Power safety detection
“EJECT P” is displayed on a TV screen. (Refer to Fig. 5.)
EJECT R
Fig. 1
EJECT T
Fig. 2
EJECT C
Fig. 3
Fig. 4
EJECT D
EJECT P
Fig. 5