background image

www.philips.com/lighting

Printed in EU

Data Subject to change without notice

Version date : 31/01/2014

4443 160 03843

1

2

SERVICE: (DRIVER / BATTERY REPLACEMENT)

 The batteries have a life time expectancy of 4 years.

 Light source (LED) is not replaceable

.

Maintenance instructions

To assure the lighting quality of this unique LED lighting concept there are only a few
instructions regarding the maintenance of this LED luminaire:

  *  Do not touch electronic components!
     Electronic components maybe under high voltage.
  *  Do not stare into LED light beam.
  * The luminaire shall be installed by a qualified electrician and wired in accordance with
     the latest IEE electrical regulations or the national requirements.
  *  Above average concentraion of sulfur effects the useful lifetime of the product.
     E.g: Light color changes from white to blue. Typically in chicken & pig farms.
 *   Periodic tests should be performed according to EN 50172:2004, clause 7.2.3 and 7.2.4.
     Each month the driver is running in emergency mode for 30 seconds.
     Once a year a full discharge cycle of at least 1 hr or 3 hrs (depending on product installed)
     should be performed.

A T T E N T I O N

OBSERVE PRECAUTIONS

FOR HANDLING

ELECTROSTATIC

SENSITIVE

DEVICES

MAXIMAL SCREWDRIVER SIZE: 8MM

A) OPEN LUMINAIRE

B) DECOUPLE BATTERY WIRES

LED22S

LED34S

LED40S

LED60S

Ipeak [A]

21

19

22

19

Twidth [μs]

255

275

235

275

Drivers / MCB 16A type B [max.]

24

24

24

24

Drivers / MCB 10A type B [max.]

15

15

15

15

Drivers / MCB 16A type C [max.]

40

40

40

40

Drivers / MCB 10A type C [max.]

24

24

24

24

Max. Nr of products

C) UNTIGHT BATTERY

 SCREWS

C   0-180 PLANE

C 90-270 PLANE

0

-5

-10

-15

-20

-25-30

-35

-90

-45

5

10

15

20

25

30

35

40

45

0

20

40

60

80

100

-40

90

LIGHT INTENSITY

DISTRIBUTION CURVES

EMERGENCY MODE

Summary of Contents for CoreLine WT120C LED18S/840 PSU L600

Page 1: ...нтажy Instruzioni di montaggio Monteringsvejledning Instrukcja montazu Návod k montáži IP65 220 V V 240 IK08 A F E B C D CLASS I 35 C 20 C GLOW WIRE 850vC LIFETIME 50k HRS 4 5Nm OPTIONAL ANTI VANDAL MOUNTING x 2 ACCESSORIES INCLUDED IN BOX Eu60 1 A B C D E F WT120C LED18S 840 PSU L600 1800 661 388 19 0 93 6 WT120C LED22S 840 PSU L1200 2200 23 WT120C LED40S 840 PSU L1200 4000 41 WT120C LED34S 840 P...

Page 2: ...s com lighting Printed in EU Data Subject to change without notice Version date 21 03 2014 4443 160 02896 N L N L N L O 20mm 2 N L N L 45 30 8 q0 75 2 5mm O5 10mm THROUGH WIRING O5 10mm q0 75 2 5mm 8 30 45 L N 3 ...

Page 3: ...www philips com lighting Printed in EU Data Subject to change without notice Version date 21 03 2014 4443 160 02896 REMOVE PROTECTION FILM 5 4 FUNCTIONAL EARTH WHERE APPLICABLE ...

Page 4: ...to LED light beam The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements Above average concentraion of sulfur effects the useful lifetime of the product E g Light color changes from white to blue Typically in chicken pig farms A T T E N T I O N OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITI...

Page 5: ...aggio Monteringsvejledning Instrukcja montazu Návod k montáži IP65 220 V V 240 IK08 A F E B C D CLASS I GLOW WIRE 850vC LIFETIME 50k HRS 4 5Nm OPTIONAL ANTI VANDAL MOUNTING x 2 ACCESSORIES INCLUDED IN BOX Eu60 1 standard mode EL mode A B C D E F WT120C LED22S 840 PSU L1200 EL1 2 3 WT120C LED22S 840 PSU L1200 EL3 2 5 WT120C LED40S 840 PSU L1200 EL1 2 3 WT120C LED40S 840 PSU L1200 EL3 2 5 WT120C LED...

Page 6: ...a Subject to change without notice Version date 31 01 2014 4443 160 03843 O 20mm THROUGH WIRING 3 N 1 2 N 1 2 2 N 1 45 30 8 q0 75 2 5mm O5 10mm 2 N 1 2 2 N 1 45 30 8 q0 75 2 5mm O5 10mm 4 UN SWITCHED NON MAINTAINED LINE SWITCHED MAINTAINED LINE ...

Page 7: ...www philips com lighting Printed in EU Data Subject to change without notice Version date 31 01 2014 4443 160 03843 REMOVE PROTECTION FILM 5 D 5 5 A 5 B 5 C 2X 6 2 1 2 ...

Page 8: ...lifetime of the product E g Light color changes from white to blue Typically in chicken pig farms Periodic tests should be performed according to EN 50172 2004 clause 7 2 3 and 7 2 4 Each month the driver is running in emergency mode for 30 seconds Once a year a full discharge cycle of at least 1 hr or 3 hrs depending on product installed should be performed A T T E N T I O N OBSERVE PRECAUTIONS F...

Reviews: