READ AND FOLLOW ALL SAFETY INSTRUCTIONS

! IMPORTANT SAFEGUARDS !

WHEN USING ELECTRICAL EQUIPMENT, BASIC

SAFETY PRECAUTIONS SHOULD ALWAYS BE 

FOLLOWED, INCLUDING THE FOLLOWING:

SAVE THESE INSTRUCTIONS

THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY.  

THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

© Philips Emergency Lighting

A Division of Philips Electronics North America Corporation

236 Mt. Pleasant Rd. • Collierville, TN USA 38017-2752 • Tech Support 888-263-4638 • Fax 901-854-1630 • www.philips.com/bodine

75000400

FLUORESCENT EMERGENCY BALLAST

  1.  To prevent high voltage from being present on red & yellow output leads prior to installation, inverter  
    connector must be open. Do not join inverter connector until installation is complete and AC power is  
    supplied to the emergency ballast.
  2.  This product is for use with most 16 W through 40 W (2' -4') T8, T9, T10, or T12 (including T12 HO) 
    fluorescent lamps, 18 W through 28 W (4-pin) twin, quad, and triple twin-tube, and 18 W through 39 W
     rapid-start long compact lamps.
  3.  Make sure all connections are in accordance with the National Electrical Code and any local regulations.
  4.  To reduce the risk of electric shock, disconnect both normal and emergency power supplies and  

 

    inverter connector of the emergency ballast before servicing.
  5.  This emergency ballast is for factory or field installation in either the ballast channel or on top of the
    fixture.
  6.  This product is for use in indoor fixtures except air handling heated air outlets, and wet, damp, or    
    hazardous locations.
  7.  An unswitched AC power source is required (120 or 277 VAC, 60 Hz).
  8.  Do not install near gas or electric heaters.
  9.  Do not attempt to service the battery. A sealed, no-maintenance battery is used that is not field
    replaceable.  Contact the manufacturer for information on service.
 10.  The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
 11.  Do not use this product for other than intended use.
 12.  Servicing should be performed by qualified service personnel.

09/14/09

B54

Ni - Cd

Installation Instructions

4 HOUR EMERGENCY OPERATION

Summary of Contents for Bodine B54

Page 1: ... triple twin tube and 18 W through 39 W rapid start long compact lamps 3 Make sure all connections are in accordance with the National Electrical Code and any local regulations 4 To reduce the risk of electric shock disconnect both normal and emergency power supplies and inverter connector of the emergency ballast before servicing 5 This emergency ballast is for factory or field installation in ei...

Page 2: ...ed below STEP 2 INSTALLING THE TEST SWITCH Refer to the illustrations above and install the test switch through the ballast channel cover of a troffer or through the side of a strip fixture Drill a 1 2 hole and install the switch as shown Refer to the diagrams below and wire the test switch so that it removes AC power from both the emergency ballast and the AC ballast at the same time For installa...

Page 3: ...AC ballast and lamp s Make sure all connections are in accordance with the National Electrical Code and any local regulations After installation is complete supply AC power to the emergency ballast and join the inverter connector At this point power should be connected to both the AC ballast and the emergency ballast and the Charging Indicator Light should illuminate indicating the battery is char...

Page 4: ... RED RED BLUE BLUE AC BALLAST BLUE BLUE WHT YELL BLK YELLOW RED FIG 1a ONE 1 16 40 W LAMP WITHOUT AC BALLAST WIRING DIAGRAMS for Emergency Only fixtures FIG 14a FOUR 4 LAMP INSTANT START BALLAST FIG 51a FOUR 4 LAMP RAPID START BALLAST INVERTER CONNECTOR RED WHITE ORANGE BLACK WHITE VIOLET BROWN 277 V 120 V COM CHARGING INDICATOR LIGHT TO UNSWITCHED AC USE PROPER TAP CAP UNUSED LEAD EMERGENCY BALLA...

Reviews: