Installation & Setup Guide
Palette II Lighting Control Console
1 2
Installation and Power Up
3. Remote Focus Unit (RFU)
The Remote Focus Unit (sold separately) is an optional
remote Ethernet device that can be connected to the
console using either a wired or wireless configuration.
The two connection options are as follows:
• CAT5 twisted-pair Ethernet cable from the back of
the console to the RFU. (The configuration can be
routed through walls, hubs, switches, etc.)
• CAT5 twisted-pair Ethernet cable from the back of
the console to a wireless Access Port; and then from
the Access Port though the air to the RFU with wire-
less receiver.
4. Vision.net
The console can interface with Strand Vision.net systems. In this configuration, the console’s DB9 Serial port can be
connected to a Vision.net RS232 Programming Station, which in turn connects to a Vision.net control station. The
following diagram shows a sample configuration:
Figure 3: Connecting to Vision.net
RFU
Wireless
Access
Port
CAT5 Cable
or
To RFU
Figure 2: Remote Focus Unit Connection
Vision.net
8-Button Station
(63328)
Vision.net
RS232 Station
(63035)
RS232 Serial
Port Cable
Serial Port
Summary of Contents for basicPalette II
Page 1: ......
Page 4: ...Installation Setup Guide Palette II Lighting Control Console ii Notes ...
Page 16: ...Installation Setup Guide Palette II Lighting Control Console 8 Overview Notes ...
Page 60: ...Installation Setup Guide Palette II Lighting Control Console 52 Controls Notes ...
Page 68: ...Installation Setup Guide Palette II Lighting Control Console 60 Setup Notes ...
Page 79: ...71 Palette II Lighting Control Console Installation Setup Guide A Specifications ...
Page 81: ...73 Palette II Lighting Control Console Installation Setup Guide B Software Tips ...
Page 87: ...Notes ...
Page 88: ...Part No 2 450181 010 ...