background image

Lighting Systems 

ALETTA AL1T5

Page 1 of 2 

Louver Shield, 1 T5 Lamp per Fixture, Grid Mounted

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group •

Job Information 

Type:

Job Name: 
Cat. No.: 

Lamp(s): 
Notes:

D1007

Features

1.  Housing: 

23 gauge pre-painted steel. 20 gauge available, consult factory.

2.  Lamp: 

One T5, T5HO. (by others)

3.  Faux Housing: 

Extruded Frosty acrylic.

4.  Louver:

 High purity Semi-Specular, 2-3/4" (6.99cm) opening x 1-3/8" (3.49cm) 

deep on 2" (5.08cm)ctrs with micro-prismatic side overlays. Elongated lens 
openings are 22" (55.88cm) windows. 

5.  Performance Kick Reflector:

 .020" (0.05cm) 95%-98% reflective, UV 

resistant polypropylene.

6.  Trim:

 Extruded aluminum trim, painted white, interfaces with ceiling grid or 

plaster frame by others.

Electrical

Ballasts are electronic and high power factor.  Dimming ballasts are available on 
many lamp types, please consult factory regarding specific applications.  1325 
max lumen battery pack is standard.  See application table on page 2 for output 
with specific lamp types.  Continuous luminaires utilize 12 gauge through wires. 
Factory installed ballast disconnect allows the ballast to be disconnected from and 
reconnected to incoming power under load without turning the entire circuit off.

Mounting

Housing is suspended by hanger wires and laid into standard or slot-T grid ceiling.  
Mounting accessory available for drywall installations (see page 2).

Labels

UL, cUL and I.B.E.W.

Ordering Instructions

Individual Fixtures:
1.

  Order quantity of Individual Units required.

Continuous Runs:
1.

  Order one Starter and one Ender fixture per run.

2.

  Order appropriate quantity of Joiner fixtures.

Continuous runs only - Prior to installing Aletta in a grid ceiling, the installing 
contractor must ensure that the fixture will set into two main runners, spaced 2' 
(60.96cm) on center.  No grid cross members are required except at the beginning 
and end of the run.

7.00”

(17.78cm)

23.00”

(58.42cm)

2.00”

(5.08cm)

2.75”

(6.99cm)

24.00” (60.96cm)

5.28”

(13.41cm)

7.00”

(17.78cm)

1

2

5

3

4

6

Louver w/ Elongated 

Lens Detail

* For dimming, use "D" option. If "D" is not selected, ballast will be static.

Ordering Information

Family

Shielding

Length

Lamps

Lamp Type

Ballast Factor

Voltage

Housing

Option

A

1

Aletta

LE

 = Louver w/ 

Elongated Lens

2

 = 2' (60.96cm)

4

 = 4' (121.92cm)

= 1 Lamp

T5 

= T5 Standard 

Output

HO 

= T5 High 

Output

10 

= *1.0 T5, 

HO Dimming 
and Static

11 

= 1.15 T5

= 120v

= 277v

= 347v

= Individual Unit

= Starter

= Joiner

= Ender

= Dimming

 

= EM Pack

= 2 Circuit

= 4 Through Wire

= 5 Through Wire

Reviews: