Lighting Systems
ALETTA AL1T5
Page 1 of 2
Louver Shield, 1 T5 Lamp per Fixture, Grid Mounted
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group •
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
D1007
Features
1. Housing:
23 gauge pre-painted steel. 20 gauge available, consult factory.
2. Lamp:
One T5, T5HO. (by others)
3. Faux Housing:
Extruded Frosty acrylic.
4. Louver:
High purity Semi-Specular, 2-3/4" (6.99cm) opening x 1-3/8" (3.49cm)
deep on 2" (5.08cm)ctrs with micro-prismatic side overlays. Elongated lens
openings are 22" (55.88cm) windows.
5. Performance Kick Reflector:
.020" (0.05cm) 95%-98% reflective, UV
resistant polypropylene.
6. Trim:
Extruded aluminum trim, painted white, interfaces with ceiling grid or
plaster frame by others.
Electrical
Ballasts are electronic and high power factor. Dimming ballasts are available on
many lamp types, please consult factory regarding specific applications. 1325
max lumen battery pack is standard. See application table on page 2 for output
with specific lamp types. Continuous luminaires utilize 12 gauge through wires.
Factory installed ballast disconnect allows the ballast to be disconnected from and
reconnected to incoming power under load without turning the entire circuit off.
Mounting
Housing is suspended by hanger wires and laid into standard or slot-T grid ceiling.
Mounting accessory available for drywall installations (see page 2).
Labels
UL, cUL and I.B.E.W.
Ordering Instructions
Individual Fixtures:
1.
Order quantity of Individual Units required.
Continuous Runs:
1.
Order one Starter and one Ender fixture per run.
2.
Order appropriate quantity of Joiner fixtures.
Continuous runs only - Prior to installing Aletta in a grid ceiling, the installing
contractor must ensure that the fixture will set into two main runners, spaced 2'
(60.96cm) on center. No grid cross members are required except at the beginning
and end of the run.
7.00”
(17.78cm)
23.00”
(58.42cm)
2.00”
(5.08cm)
2.75”
(6.99cm)
24.00” (60.96cm)
5.28”
(13.41cm)
7.00”
(17.78cm)
1
2
5
3
4
6
Louver w/ Elongated
Lens Detail
* For dimming, use "D" option. If "D" is not selected, ballast will be static.
Ordering Information
Family
Shielding
Length
Lamps
Lamp Type
Ballast Factor
Voltage
Housing
Option
A
1
Aletta
LE
= Louver w/
Elongated Lens
2
= 2' (60.96cm)
4
= 4' (121.92cm)
1
= 1 Lamp
T5
= T5 Standard
Output
HO
= T5 High
Output
10
= *1.0 T5,
HO Dimming
and Static
11
= 1.15 T5
1
= 120v
2
= 277v
3
= 347v
U
= Individual Unit
S
= Starter
J
= Joiner
E
= Ender
D
= Dimming
E
= EM Pack
2
= 2 Circuit
4
= 4 Through Wire
5
= 5 Through Wire