Alignments
6.
6.5
Reset of Repaired SSB
A very important issue towards a repaired SSB from a Service
repair shop (SSB repair on component level) implies the reset
of the NVM on the SSB.
A repaired SSB in Service should get the service Set type
“00PF0000000000” and Production code “00000000000000”.
Also the virgin bit is to be set. To set all this, you can use the
ComPair tool or use the “NVM editor” and “Dealer options”
items in SAM (do not forget to “store”).
After a repaired SSB has been mounted in the set (repair on
board level), the type number (CTN) and production code of the
TV has to be set according to the type plate of the set. For this,
you can use the NVM editor in SAM. The loading of the CTN
and production code can also be done via ComPair (Model
number programming).
In case of a display replacement, reset the “Operation hours
display” to “0”, or to the operation hours of the replacement
display.
42PFL3606H/58
LGD LC420WUY-SCB1
123
42PFL3606H/60
LGD LC420WUY-SCB1
123
CTN_ALT BOM#
Panel Type
Display Code