25
Hudson 150B
DDC Instructions
Modify Analog DDC data (Serial No.)
1. Click
icon on the tools bar.
2. Click
till the Step 7 of 9 window appears.
3. Type the new Serial No. (for example, TY 123456).
4. Click
till the last step window appears, then click
to
exit the Step window.
Load DDC data from file
1. Click
from the tools bar.
2. Select the file you want to open.
3. Click .
Button.
Save DDC data as a file
Sometimes, you maybe need to save DDC data as a text file for using
on other DDC chip. To save DDC data, follow the steps below:
1. Click
icon on the tools bar and type a file name you like. The
file format is ddc type which can be open by Microsoft WordPad.
2. Click
button.
Note: During the loading, EDID301 will verify the EDID data which just
loaded from monitor before proceed any further function, once
the data structure of EDID can not be recognized, the following
error message will appear on the screen (Fig. 8). Please confirm
following steps to avoid this message.
1. The data structure of EDID was incorrect.
2. DDC IC that you are trying to load data is empty.
3. Wrong communication channel has set at configuration setup
windows.
4. Cables loosed or poor contact of connection.
Fig. 8
Analog DDC serial number
Write DDC data to monitor
1. Click
icon from the tools bar to starting rewrite DDC data.
2. Click
for confirmation.