19
DDC Instructions
107S2 CM23 GSIII
Loading DDC data from monitor
1. Click
icon on the tools bar to bring up the Configuration Setup
windows as Fig.7
2. Select the DDC2B as the communication channel.
3. Enable Factory memory data write function and fill in page address
“FA” to the block.
4.. Click
button to confirm your selection.
Note: The Factory memory data write function will allow EDID301 to
rewrite the serial numbers of Software DDC data in main
EEPROM.
5. Click
button. The main menu appears (as shown on Fig. 6).
Fig. 6
Note: If the connection is improper, you will see the following error
message before entering the main menu. Meanwhile, the
(read EDID) function will be disable. At this time, please make
sure all cables are connected correctly and fixedly, and the
procedure has been performed properly.
4. Click
icon to read DDC EDID data from monitor. The EDID
codes will display on screen as following. (The EDID codes are
dependent on the model.)
Command bar
Tools bar
Status bar
Fig. 7
Modify DDC data (Serial No.)
1. Click
icon on the tool bar.
2. Click
till the Step 7 of 9 window appears.
3. Type the new Serial No. (for example, TY 123456).
4. Click
till the last step window appears, then click
to
exit the Step window.
Note: During the loading, EDID301 will verify the EDID data which just
loaded from monitor before proceed any further function, once
the data structure of EDID can not be recognized, the following
error message will appear on the screen (Fig. 8). Please confirm
following steps to avoid this message.
1. The data structure of EDID was incorrect.
2. Software DDC Data that you are trying to load data is empty.
3. Wrong communication channel has set at configuration setup
windows.
4. Cables loosed or poor contact of connection.
5. Software DDC only is disable.
Fig. 8
1
F0
http://jdwxzlw.5d6d.com/?fromuser=华盛维修
家电维修资料网,免费下载各种维修资料