background image

System Monitor PSM 2  

 

 

REV 1A – Software V3 

 Page 3 

The System Monitor PSM2 is designed for the supervision and control of all philippi 
components that are connected to the PBUS system. It is the main display and 
operational interface, and the electrical system can be supervised, operated and 
controlled using the PSM2 system monitor. Additional System Monitors PSM2 can be 
added to show different information simultaneously at the same location or at various 
locations to enable monitoring and control from multiple stations. These monitors will 
allow all information to be shown independent of each other.  
The System Monitor PSM2 operates as a central monitor, and the system can be 
easily expanded from a simple battery monitor comprising of a PBUS system monitor 
plus a battery Shunt SHC, up to a multi-functional monitor and control panel in a 
digitally switched CAN-bus system. 

1 Safety references 

Unauthorised change to the equipment will invalidate the CE sign.  
The installation of the PSM2 should be made only by electrical specialists. 
Before connection of the PSM2, the battery terminals must be disconnected. 
Important - pay attention to the correct polarity of the batteries! 
The inlet of the power supply must be protected by a fuse of a suitable rating. 
The assembly and operating instruction is a component of the PSM2 package. It must 
be kept (for reference). Importantly: - for later maintenance work - and for the use of 
subsequent owners of the equipment. 

1.1 Exclusion of liability 

Both adherence to the operating instruction, and the conditions and methods used 
during installation, use, and maintenance of the PSM2 cannot be supervised by  
philippi elektrische systeme gmbh. Therefore, we do not take any responsibility for 
loss, damage or costs, which develop due to incorrect installation and/or inappropriate 
use or operation. 

1.2 Warranty 

philippi elektrische systeme gmbh grants a two-year limited warranty due to our „terms 
of sale and delivery - passage 7" for our devices. This “terms of sale and delivery” are 
the basis of all our sales and deliveries. They are printed in our catalogues and part of 
all quotations and delivery confirmations. 
 
 
 
 
 
 
 
 

Summary of Contents for PSM 2

Page 1: ...PSM 2 REV 1A Software V3 Page 1 INSTRUCTION MANUAL System Monitor PSM 2 philippi elektrische systeme gmbh www philippi online de Neckaraue 19 info philippi online de D 71686 Remseck am Neckar Tel 49 7146 8744 0 Fax 22 ...

Page 2: ...ed to the PBUS 7 5 3 Adjustment of the operational parameters 7 6 PSM Setup 7 6 1 Setup Display 8 6 2 P BUS Network 9 6 3 Data Logging 10 6 4 Device 10 6 5 Alert management 10 6 5 System time 11 6 7 Consumer digital switch 11 7 Operation 13 7 0 Alarm display 13 7 1 Submenu battery 14 7 2 Submenu Tank 15 7 2 1 Features of Tanks 15 7 2 2 Power save Mode CMT2 15 7 2 3 Troubleshooting tank sensors 16 ...

Page 3: ...stallation of the PSM2 should be made only by electrical specialists Before connection of the PSM2 the battery terminals must be disconnected Important pay attention to the correct polarity of the batteries The inlet of the power supply must be protected by a fuse of a suitable rating The assembly and operating instruction is a component of the PSM2 package It must be kept for reference Importantl...

Page 4: ...echnical data Nominal voltage DC 8 32 V Power consumption 100 mA 12 V operating at 100 illumination 5 mA 12 V at stand by mode illumination 0 Dimensions 105 x 105 x 40 mm Cut out 88 x 88 mm Software Versions FEB 2017 VERSION 1 First Version MRZ 2017 VERSION 2 Second version with temperature display JUN 2017 VERSION 3 Third version with integration of PSS EM box V3 4 Installation 4 1 Necessary equi...

Page 5: ...y time The necessary installation cut out is 88 x 88mm 3 5 x 3 5 the necessary minimum depth is 40mm 1 6 4 3 System arrangement PBUS All PBUS components are connected via a PBUS network cable The components can be in any order or sequence Ensure that the terminators are installed at each end of the network Without these terminator resistors the PBUS will not function ...

Page 6: ...more time it s going to switch back into day mode 3 Display of Time 4 Display of the alarm list 5 Settings Gear Before using the PSM2 System Monitor for the first time it is necessary to connect all components to the PBUS network and ensure that they are all powered up When this is accomplished the PSM2 System Monitor will recognise all the devices connected to the network and will add them to its...

Page 7: ...ion is only available on the PSM2 Monitor with the ID 0 If additional Displays are added they must have different addresses i e 1 2 etc If duplicate devices are listed after the device login you to have to press the button Renew device addresses in order to reset the sub addresses of the connected and active PBUS components 5 3 Adjustment of the operational parameters After identification of all d...

Page 8: ...monitor Standby To save energy and reduce glare the PSM2 display will enter a standby mode of reduced brightness after an adjustable delay The delay is adjustable from 20 to 250 seconds after the last operation If you choose any value under 20 the PSM2 won t enter standby mode Start page You can set the page that the PSM2 System Monitor displays when powered up as either the main menu or one of th...

Page 9: ... Renew device addresses By pressing this button all sub addresses of the connected and active PBUS network components are reset This will only be required if new components are added which have been used on other PBUS networks and where the possibility of duplicate addresses may exist NOTE This function should only be used in the case noted above otherwise the allocation and display order of conne...

Page 10: ...djusted between 1 minute up to max 60 minutes For each device group it can be defined if the data should be recorded 6 4 Device In this submenu all through the PBUS connected devices get configurated Please refer to the appropriate manuals of the individual PBUS compatible devices 6 5 Alert management For the display of battery energy main switch and tank alert the alert notification can be activa...

Page 11: ...s it easier to assign the alerts temporal The time and date can be adjusted through the keypad Should the clock have deviations they can be adjusted through the Setup System Time Thereby 1 Hz comply with a deviation of 2 6 seconds per day If the monitor starts with the date set to 1970 the time must be adjusted accordingly If the installed header is empty the battery must be removed and replaced T...

Page 12: ...itching commands the node address under which the PSM2 sends his switching commands must be registered here Number of Pages The number indicates how many consumer pages each with 6 buttons are displayed in the PSM2 The maximum number of pages is limited to 4 which results in 24 switch functions Start page Indicates which consumer page is shown first Button X For each button screen button it s poss...

Page 13: ...activated subitems 7 0 Alarm display An activated alert notification is displayed through a green alert symbol In case of an alarm the alert symbol will change its colour to red A list with all present alarms will appear as soon as a new alarm is reported If you ve chosen Message Buzzer in the alert management a new alarm will be indicated through an acoustical and optical signal the screen is goi...

Page 14: ...ty until the battery is completely discharged deep discharge A deep discharge should be strictly avoided as the battery will almost certainly be permanently damaged If the shunt SHC determines that the point of deep discharge has arrived sooner than it should normally be e g by aging the unusable part will be displayed in the dark grey area Appears in the battery symbol the message Not synchronize...

Page 15: ...nt consumption when using ultrasonic sensors which draw approx 50mA per sensor the Power save mode can be activated The Power save mode is activated as soon as all PSM2 system monitors connected are in sleep mode display off At that point the measuring changes from continuous to a cyclic routine If the power supply voltage is between 11 5V and 13 V 23 V and 26 V a measurement is taken every 30 min...

Page 16: ...t rate It is also possible to see if the batteries are being charged or discharged and arrows show the direction of the current flow The charging sources are shown in the upper part of the display the loads in the lower part A Combi Inverter Charger will appear on the bottom line and will show amps being charged or consumed but will show only accumulative charging Ah In this menu all batteries are...

Page 17: ...ns Limit Limit and Sleep the corresponding operational modes can be adjusted 7 4 Submenu main switch Needed interface component FBC 265 TSC EM box This menu shows the position of the main switches Main Switches can be switched on or off by touching the corresponding button If a PIN is required for actuation this will be indicated by a small padlock in the switch symbol ...

Page 18: ...nected the AC parameters of voltage current frequency and the kW hours used since the last reset are shown in the symbol on the lower line 7 6 Submenu AC combi inverters Needed interface component Studer X tender incl interface XCOM CAN or Mastervolt Ultra incl interface CMB This screen shows the energy situation of the AC plant if a combi inverter charger is connected By touching the blue button ...

Page 19: ...west temperature with a time stamp 7 8 Consumer Needed interface component CMR4 By pressing the screen button the consumer is turned on or off An activated consumer is indicated by a green hook If you press the screen button for a longer time a new screen is going to appear to set the brightness of the lamp This option menu is only available if a dimmable LED lamp like a Prebit Slave light is conn...

Page 20: ...nd side of the rear cover The power supply can then be plugged in again and the screen should show that new software has been recognised and is being installed automatically You can see the software updating progress by a blue bar After the update is finished please remove theSD card which must be done after removing the power supply The software update is now operational If the PSM2 operates norm...

Reviews: