Battery-Monitor BLS 

 

 

 
REV 1A – APR 2019 - Software Version 1A 

page 12 

- Alarm auto off  

0-255 sec (0 = always on) 

The  buzzer  can  be  configured  for  individual  alarms.  Depending  on  the  configuration,  the  alarm 
switches on for the following alarm states and remains switched on until all pending alarms have 
been canceled. If an alarm has been acknowledged and a new alarm is added, the buzzer will be 
reactivated. 
 
Battery 1  

capacity alarm  

Adjustable (10 - 80%) 

 

battery empty (20%)  

determined by battery management 

 

battery deep discharge (0%)  

determined by battery management 

 

overvoltage adjustable  

adjustable (14 - 32 V) 

 

(Over) temperature  

adjustable (40 - 60 ° C) 

Battery 2  

undervoltage  

adjustable (9-24V) 

 

overvoltage  

adjustable (14-32V) 

Battery 3  

undervoltage  

adjustable (9-24V) 

 

overvoltage  

adjustable (14-32V) 

 
The voltage alarms must necessarily be adapted for 24V batteries! 
 
By briefly pressing the respective line, the audible alarm can be switched on or off. At long pressure 
(> 2s) the respective threshold value can be edited. 

5. OPERATION  

On the main page you can switch between the 2 main screens via the lower buttons: 
battery  and  charger,  provided  that  a  philippi  charger  ACE  with  interface  ACE-LIN  is  installed. 
Otherwise, only the battery screen is available. 
 
The lower buttons have the following functions: 
 
Batteries:  If  a  shunt  SHE  300  is  connected,  the  charge  status  of  the  battery  system  can  be  read. 
Pressing this button switches to the battery screen. 
 
AC mains: If an ACE charger is connected, the current mains voltage is displayed. If no mains voltage 
is applied to the charger this will be displayed accordingly. 
Pressing this key switches to the loading screen. 
 
SETUP: Here the settings of the battery system can be made. See chapter 4. 
 
 

Summary of Contents for BLS

Page 1: ...tery voltage the remaining operating time until the adjustable capacity alarm of the main battery the voltage of up to 2 additional batteries You have the possibility of adjusting an alarm threshold if the capacity of the main battery falls below a certain threshold when a voltage threshold is exceeded or an undervoltage occurs The battery monitor BLS constantly monitors the voltage and current of...

Page 2: ...0 3000 Battery Charger Interface ACE LIN Order No 0 8000 4975 1 3 Warranty Warranty is granted for a period of two years from the date of purchase Defects as a result Material or manufacturing defects are eliminated free of charge if The device is sent to the manufacturer free of charge The proof of purchase is enclosed The device has been treated and used as intended No foreign spare parts have b...

Page 3: ...ark The battery monitor may only be connected by qualified electricians Disconnect the battery leads before connecting the battery monitor Pay attention to the correct polarity of the batteries The power supply to the monitor and shunt must be protected This device is not intended for use by children The present installation and operating instructions are part of the component delivery It must wel...

Page 4: ...s for more than 3 months without charge the shunt should also be disconnected from the battery The following figure gives an overview of the connection of the monitor and the shunt SHE 300 The LIN bus connecting cable between the monitor and the shunt takes place via a 1 core cable This can also consist of any or existing line The cable cross section should be min 1mm and max 1 5 mm 3 2 Shunt Moun...

Page 5: ...line is used to measure the voltage of the main battery and at the same time to supply the shunt with power It is important that no further cables are connected between connection B and the battery MINUS pole since otherwise not all currents will be detected and the battery management will not be able to work All lines of the electrical system including the connecting cable to the starter battery ...

Page 6: ... or charge but is for information only 4 LIN bus communication with display The BLS monitor communicates with the Shunt SHE 300 and the ACE charger via this cable 3 3 Interface ACE LIN optional part To communicate with the BLS monitor with an ACE charger an ACE LIN interface must be inserted in the ACE charger For the ACE 12 60 and ACE 24 30 models the integrated monitor must be removed and replac...

Page 7: ... interface board the 16 pin connector of the ribbon cable must be plugged into the matching red connector on the main board of the ACE charger The interface board is held in place by three plastic clips on the case Wiring LIN line to monitor BLS Shunt SHE The communication port LIN of the interface ACE LIN is connected to the connection LIN of the shunt SHE 300 and the monitor BLS via a 1 wire con...

Page 8: ...in the delivery state appears After successful entry with subsequent confirmation OK will take you to the settings menu The following settings can be made by pressing the respective symbol 1 Display settings 2 Battery Management settings 3 Charger settings 4 Alarm settings 4 2 Anzeige After pressing the Display symbol the adjacent image appears The following settings can now be made Language EN FR...

Page 9: ...ity of the battery to be monitored must be set Please note that the capacity of the battery should only be adjusted when the batteries are 100 charged as this will set the capacity indicator to 100 and all internal counters to 0 If the battery was not fully charged at this time it is imperative to synchronize the display with the battery state of charge 4 3 3 Rated voltage Please set the rated vol...

Page 10: ...r 12V batteries before the battery has delivered its rated capacity This relationship can be mathematically determined with the Peukert equation In the residual time function this equation is used to adjust the remaining time at high discharge rates Under normal circumstances the Peukert exponent need not be changed Usually for lead batteries unless different values are available the Peukert expon...

Page 11: ...arm can always be acknowledged in advance by touching the screen or can automatically switch off after a definable time Alarm options Battery capacity alarms A message appears on the monitor to charge the battery battery appears red when the battery falls below the set capacity threshold The alarm capacity alarm is preset to 50 For an average application this value is usually okay However the alar...

Page 12: ...age adjustable 14 32V The voltage alarms must necessarily be adapted for 24V batteries By briefly pressing the respective line the audible alarm can be switched on or off At long pressure 2s the respective threshold value can be edited 5 OPERATION On the main page you can switch between the 2 main screens via the lower buttons battery and charger provided that a philippi charger ACE with interface...

Page 13: ...tion about the state of life of the battery With a short press on the battery icon can appear between the ads capacity in capacity in AH remaining time battery temperature change Alternatively the following error messages appear Not synchronized The shunt has been restarted and the displayed capacity value does not yet correspond to the true capacity level Then the battery group connected to the s...

Page 14: ...ws the current charging current and the charging voltage The battery icon displays the current charge phase charge charge maintain and battery temperature To the right of the battery the voltage measured by the charger and its frequency are displayed The side buttons have the following function LIMIT In order to adjust the charging current to the battery system or a weakly secured shore connection...

Page 15: ...case of mistreatment 5 1 2 Deep discharges Every complete discharge up to the lower voltage limit 9 11 5 V depending on the load is considered a deep discharge Deep discharges should be avoided at all costs as they damage the battery and premature capacity loss and lifetime reduction are expected for most battery types However should a deep discharge occur the battery must be recharged immediately...

Page 16: ...ds depending on the load the charge state is automatically set to 20 or if fully discharged to 0 If possible the unavailable capacity difference between nominal capacity and withdrawn capacity is determined and displayed as a gray area This gray area can be used as an indicator for the aging of the battery during normal discharges of less than C10 current less rated capacity 10 For high current lo...

Page 17: ...ether each charging source is recognized correctly Charging currents are always positive if all consumers are switched off at the same time This must be checked individually for each charging source At the negative pole of the battery only the shunt with the B connection must be connected nothing else 7 Software Update To update the monitors software a micro SD card is required After receiving the...

Page 18: ...onnections shunt bolt M8 9 Declaration of conformity This device complies with the requirements of the EU directives 2014 30 EC Electromagnetic compatibility Immunity EN 61000 6 1 Emitted interference EN 61000 6 3 The conformity of the device with the o g The directive is confirmed by the CE mark 10 Disposal instructions When disposing of this device observe the applicable local regulations and us...

Reviews: