background image

 

In Wall switch    PAN35

 

 

 

 

 

 

 

                                                                                     

Introduction 

This in-wall switch module is a transceiver which is a Z-Wave Plus

TM

 enabled device and is 

fully compatible with any Z-Wave

TM

 enabled network. Mini size design let the module can 

easily hide itself into the wall box and that will be good for the house decoration. 

 

There are many kind of application by using the module to switch Load On and Off, one main 

application is the light control. If connect the COM port directly to AC Line terminal, the new 

smart relay calibration technology can reduce the inrush current caused by the load and let 

the module work perfectly with many kind of light like incandescent, fluorescent and LED 

light. This module can also connect to alternative power supply like DC 12V to switch on/off 

12V MR-16 light as follow picture.

 

 

 

This  product  can  be  operated  in  any  Z-Wave  network  with  other  Z-Wave  certified 
devices from other manufacturers. All mains operated nodes within the network will 
act as repeaters regardless of vendor to increase reliability of the network.

 

 

Safety Precautions and Installation 

 

 

Avoid installing the unit in storming or raining weather. 

 

 

Be sure to isolate or switch off power source before installing or maintenance. 

 

 

Do ensure that the power supply circuit protected by a 16A circuit breaker or 
suitable equivalent fuse. 

 

 

IMPORTANT

 

 

Installation must be performed by skilled technicians who are informed about 
the standards and technical requirements of the appliance and its proper 
installation. 

 

 

Check your local codes as they apply to your situation. If the house wiring is 
of aluminum, consult with an electrician about proper wiring methods. 

 

Before  proceeding  with  the  installation,  TURN  OFF  THE  POWER  TO  THE 
LIGHTING  CIRCUIT  AT  THE  CIRCUIT  BREAKER  OR  FUSE  BOX  TO  AVOID 
ELECTRICAL SHOCK.

 

 

Specification

 

Operating Voltage

 

100 -240VAC 50Hz-60Hz

 

Maximum Load

 

Max. 6.5A x2 Channels (230Vac/120Vac) (Resistive load)

 

Range

 

Minimum 

40m    indoor

 100m outdoor line of sight

 

Operating Temperature

 

0°C - 40°C

 

Humidity

 

Up to 85% max.

 

Storage Temperature

 

-20°C to 60°C

 

Location

 

Indoor use only

 

Frequency Range

 

868.40MHz; 869.85MHz (EU) 

 

908.40MHz; 916.00MHz (USA/Canada) 

 

920.90 MHz, 921.70 MHz, 923.10 MHz (Taiwan)

 

RF Maximum Power

 

+10dBm (Peak), -10dBm (Average) 

 

OTA

 

Support

 

FCC ID

 

RHHPAN35

 

Dimensions

 

47.5 x 39 x15.6 mm

 

Wire

 

0.75mm², 18AWG

 

** Specifications are subject to change and improvement without notice. 

 

 

 
 

Summary of Contents for PAN35

Page 1: ...installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper install...

Page 2: ...ed or check max load cannot exceed 85 C 230Vac 120Vac Resistive load Installation Steps 1 Connect PAN35 to AC N and L and COM connect to L 2 Connect Load1 and Load2 to NO1 and NO2 3 Connect external Switch to S1 and S2 Fig 1 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Obs...

Page 3: ...itch can be used for inclusion or exclusion for 3 minutes after power up Pressing Include button of PAN35 three times within 2 seconds will enter exclusion mode Node ID has been excluded 2s On 2s Off No node ID Reset Pressing Include button of PAN35 three times within 2 seconds will enter inclusion mode One press one flash Within 1 second press Include button of PAN35 again for 5 seconds IDs are e...

Page 4: ... Report OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF 1 2 BASIC_SET SWITCH_BINARY_SET Since the switch has two relay both the load attached to the Switch will turn on or off upon receipt of the following commands from a Z Wave Controller Command Class Basic Basic Set Value 1 99 255 0xFF both the load atta...

Page 5: ...when endpoint set to 1 PAN35 will reply ON 0xFF when Relay 1 is ON report OFF 0x00 when Relay 1 is OFF If endpoint set to 2 PAN35 will reply state of Relay2 Below is an example show a source endpoint 5 send a Get command to PAN35 endpoint 1 COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x05 this is the endpoint of command owner here we assume endpoint is 5 if the owner doesn...

Page 6: ...ge Toggle mode 2 Restore switch state mode 1 0 2 1 0 Switch off 1 Last switch state 2 Switch on 3 1 External switch mode Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge Toggle mode default value is Edge mode Edge mode this mode is suitable for the bi stable wall switch that has indicator point on the switch and the same position correspond to same state of relay1 and relay2 if t...

Page 7: ...hout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation...

Page 8: ...erference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 警語 警語 警語 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更 頻率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全...

Reviews: