Philio Technology Corporation PSP05 Manual Download Page 1

Motion Sensor   PSP05    

                    

              PSP05-A                                        PSP05-B

              

PSP05-C                                        PSP05-D 

          

The   motion   sensor   PSP05  has   PIR   function,   based   on  Z-Wave

TM

technology.

This device is a Security Enabled Z-Wave Plus Product. Z-Wave

TM

 is a

wireless   communication   protocol   designed   for   home   automation,

specifically   to   remotely   control   applications   in   residential   and   light

commercial environments. The technology uses a low-power RF radio

embedded or retrofitted  into home electronics devices  and systems,

such   as   lighting,   home   access   control,   entertainment   systems   and

household appliances.

This product can be included and operated in any Z-Wave

TM

  network

with other Z-Wave

TM

 certified devices from other manufacturers and/or

other applications.  All non-battery operated nodes within the network

will act as repeaters regardless of vendor to increase reliability of the

network. 

The device adopt the Z-Wave

TM

  500 series chip, when your Z-Wave

TM

network   system   is   all   made   by   Z-Wave

TM

  500   series   devices.   The

network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

CAUTION

–   replacement  of a battery with an incorrect type that  can defeat a
safeguard (for example, in the case of some lithium battery types);

– disposal of a battery into fire or a hot oven, or mechanically crushing
or cutting of a battery, that can result in an explosion;
–   leaving   a   battery   in   an   extremely   high   temperature   surrounding
environment that can result in an explosion or the leakage of flammable
liquid or gas;
– a battery subjected to extremely low air pressure that may result in an
explosion or the leakage of flammable liquid or gas

The marking information is located at the bottom of the apparatus. 

1

Summary of Contents for PSP05

Page 1: ...o increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication CAUTION replacemen...

Page 2: ...ion temperature 10 to 40 C Humidity 85 RH max FCC ID RHHPSP05 Marking CE NCC Specifications are subject to change and improvement without notice Function Compare A B C D Model Description PSP05 A Wall mount PSP05 B Ceiling mount with Square shape PSP05 C Ceiling mount with Round shape PSP05 D Wall mount with lens cover Troubleshooting Symptom Cause of Failure Recommendation The device can not join...

Page 3: ...s lost or otherwise inoperable 1 Pressing button four times and keep about 5 seconds 2 IDs are excluded and all settings will reset to factory default Association 1 Have Z WaveTM Controller entered association mode 2 Pressing button one time to enter the association mode Note The device support 2 groups The group 1 is for receiving the report message like triggered event temperature illumination e...

Page 4: ... report Every 6 hours report once in default It could be changed by setting the configuration NO 10 Low battery report When the battery level is too low every 30 minutes will report once Notice The configuration NO 10 could be setting to zero to disable the auto report And the configuration NO 20 could change the tick interval the default value is 30 if setting to 1 that means the minimum auto rep...

Page 5: ... function when installation Normal Mode is for the normal operation Operation Mode can be switched by pressing button or tamper key two times LED can indicate which mode it is Lighting on one second means entering test mode flashing once means entering normal mode When the event triggered normally the LED won t indicated unless the battery is in the low level the LED will flash once But in the Tes...

Page 6: ...ser execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_WAKE_UP_V2 COMM...

Page 7: ...oom 0 In the same room Default 1 In the different room Notice If this bit is 1 it is recommended also set the Bit1 to 1 cause the PIR triggered doesn t mean the people in that room NO Name Def Valid Description 0 Bit4 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light 1 Disabl...

Page 8: ...No 20 20 Auto Report Tick Interval 30 128 127 The interval time for auto report each tick Setting this configuration will effect configuration No 10 NO Name Def Valid Description The unit is 1 minute Caution1 Setting to 0 means turn off all auto report function Caution2 The range is from 0x00 0xFF using hexadecimal notation Disposal This marking indicates that this product should not be disposed w...

Page 9: ...ept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Warning Do not dispose of electrical applian...