background image

 
 

 

 

2. FOR YOUR SAFETY         

 

Your safety is the most important thing we concerned! 

Please read this manual carefully and fully understand before operating your 

dehumidifier. 

2.1        OPERATIONALPRECAUTIONS 

WARNING- to reduce the risk of fire, electric shock or injury to persons or property: 

 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 

similarly qualified persons in order to avoid a hazard. 

 

The appliance shall be disconnected from its power source during maintenance. 

 

Always operate the unit from a power source of equal voltage, frequency and rating as 

indicated on the product identification plate. 

 

Always use a power outlet that is grounded. 

 

Unplug the power cord when cleaning or when not in use. 

 

Do not operate with wet hands. Prevent water from spilling onto the unit. 

 

Do not immerse or expose the unit to rain, moisture or any other liquid. 

 

Do not leave the unit running unattended. Do not tilt or turn over the unit. 

 

Do not unplug while the unit is operating. 

 

Do not unplug by pulling on the power cord. 

 

Do not use an extension cord or an adapter plug. 

 

Do not put objects on the unit.   

 

Do not climb or sit on the unit.   

 

Do not insert fingers or other objects into the air outlet. 

 

Do not touch the air inlet or the aluminum fins of the unit. 

 

Do not operate the unit if it is dropped, damaged or showing signs of product malfunction. 

 

Do not clean the appliance with any chemicals.   

 

Ensure the unit is far away from fire, inflammable, or explosive objects. 

Summary of Contents for TeraDRY 12

Page 1: ...INSTRUCTION MANUAL TeraDry 12 17 210 6203280 Website www philco gr e mail sales lozos eu Service 210 620 3838 Fax 210 620 3279...

Page 2: ...TeraDry 12 PHILCO Serviceworld 1 1 1 R290 R290 ODP GWP R290 warning service...

Page 3: ...1 2 8 R 290 R 290 R290 R290 R290 R290...

Page 4: ...2 2 1 service...

Page 5: ...4m service 2 2 R290 2 2 1 2 2 2...

Page 6: ...2 2 3 2 2 4 2 2 5 2 2 6 2 2 7 2 2 8 service...

Page 7: ...2 2 9 3 i Sense...

Page 8: ...3 1 TeraDRY 12 12L D 30 RH80 AC220 240V 50Hz 200W 1 2A 30 RH80 38dB A 2 0L R290 50g 10kg design pressure High Side 3 2MPa Low Side 0 7MPa 255 220 445mm...

Page 9: ...4 4 1 30 4 m...

Page 10: ...4 2 5 C 35 C 45 24 3 3 3 5 5 1...

Page 11: ...Power 1 60 Mode 3 3 3 30 10 5 30 80 3 5...

Page 12: ...0 24 1 00 LED LED POWER Child lock Lock 3 i Sense 3 1 45 2 45 65 3 65 E0 E2 CL CH LO HI...

Page 13: ...1 On Off On Off...

Page 14: ...1 PVC 2 1 2 3 2 3 4...

Page 15: ...1 2 3...

Page 16: ...1 5 C 35 C 5 C 16 C 2 Drain water tank and reset it or re position the water tank to right place 5 C 35 C E2 LO 20 HI 90 CL 5...

Page 17: ...CH 38 1 2 3 4 5 6 7 10...

Page 18: ...1 2...

Page 19: ...y R290 is used as the refrigerant R290 has no damaging influence on the ozone layer ODP a negligible greenhouse effect GWP and is available worldwide Because of its efficient energy properties R290 is...

Page 20: ...to the atmosphere R 290 propane is flammable and heavier than air It collects first in low areas but can be circulated by the fans If propane gas is present or even suspected do not allow untrained pe...

Page 21: ...use a power outlet that is grounded Unplug the power cord when cleaning or when not in use Do not operate with wet hands Prevent water from spilling onto the unit Do not immerse or expose the unit to...

Page 22: ...n openings clear of obstruction The appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation Any person who is involved with work...

Page 23: ...s aware of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants i e no sparking adequately sealed or intrinsically safe...

Page 24: ...nce of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected refrigeration pipe or components are installed in a position wh...

Page 25: ...Y 12 Dehumification Capacity 12L D 30 RH80 Rated Voltage AC220 240V 50Hz Max rated Input Power Current 200W 1 2A 30 RH80 Noise 38dB A Water Tank Capacity 2 0L Maximum Refrigerant Charge R290 50g Net w...

Page 26: ...radiators heat registers stoves or other products that products that produce heat In an area where oil or water may be splashed Direct sunlight Mechanical vibration or shock Excessive dust Lack of ve...

Page 27: ...o set upright for at least 24 hours before start up Keep doors and windows close for better energy saving Do not operate or store the unit in direct sunlight or rain It is normal for air outlet to fee...

Page 28: ...umidity can be adjusted under auto mode Continuously drying mode The machine continues to run but the humidity cannot be adjusted Sleeping mode Touch the sleep button the button lights up and start th...

Page 29: ...n on the machine The wind speed can only be adjusted in the automatic mode Press this key to switch the high and low wind speed The corresponding wind speed indicator lights up Long press this key to...

Page 30: ...area with a drain or outside Clean the inside of the tank as well as the outside Replace the empty tank back into the unit Press the POWER button to resume operating If the Water Full light does not e...

Page 31: ...attached drain hose to the unit Condensate water can be automatically flow into a bucket or drain by gravity 1 Straighten the drainage pipe 2 Insert one end of the drain into the drain into the cister...

Page 32: ...s regular cleaning The air filter is removable for easy cleaning Do not operate the unit without an air filter or the evaporator may be contaminated 1 Take the water tank from the body and then pull o...

Page 33: ...ull Indication Flashes Drain water tank and reset it or re position the water tank to right place Room temperature 5 C or 35 C Self Protection designed to protect the unit Can not work under such temp...

Page 34: ...ry non corrosive gas and safe place indoor ATTENTION The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds Unplug the unit and place it in...

Page 35: ...s cable and discard it WARNING During using service and disposal the appliance please pay attention to symbol as left side which is located on rear of appliance rear panel or compressor It s risk of f...

Page 36: ...www serviceworld gr AUTHORISED SERVICE CENTER 210 620 38 38...

Reviews: