Philco PDL25 User Manual Download Page 21

                                                                                                           

8. Timer 

(1)Timer Off: 

When  appliance  is  powered  on,  presses  Timer  1H/2H/4H/8H  for  the  reservation  of 

operating, timer symbol displayed on LED screen. 

(2)Time On: 

When appliance is powered off, press  Timer 1H/2H/4H/8H for power off, timer symbol 

displayed on LED screen.     

4

Water Full 

When tank is full, device will automatically shut off and buzzer will alarm 10 times. At 

the meantime, the LED light of power and “full" illuminate.   

5

Memory function 

1

If  user  turn  off  unit  and  device  is  in  stand-by  ,  the  device  will  memory  the  last 

setting if user turn on again. 

2

If power failure , the machine can not restart automatically and there is no memory 

function. 

3

If user set “child lock” and “timer”, device will shut off when time is up , but no 

memory on child lock when turn on unit again.   

6

Automatic Defrosting:   

If  the  temperature  sensor(NTC)  detects  that  the  temperature  on  the  copper  tube  of 

evaporator is 

-1

, the compressor will stop and the dehumidifier starts to defrost. The 

light  of  Defrost  is  illuminated.  The  compressor  will  only  start  working  again  after  10 

minutes’  defrosting  and  the  temperature  on  the  copper  tube  is 

2

,  the  dehumidifier 

will work as the same status as before, the light of Defrost is off. 

(Note: 

,  when  the  dehumidifier  is  defrosting  under  “Dehu”  mode  then  the  fan  motor 

Summary of Contents for PDL25

Page 1: ......

Page 2: ......

Page 3: ...2 3 5 6 7 1 7 2 7 3 7 4 9 5 9 6 9 7 10 8 10 9 10 10 11...

Page 4: ...3 1 2 3 4 5 6 7 8...

Page 5: ...4 9 10 11 12 13 14 15 16...

Page 6: ...5 1 5 35 2 3 4...

Page 7: ...6...

Page 8: ...7 1 2 1 2 Mode 3 Set 4 Timer 5 Speed 6 Swing 7 Ion 8 Lock 3 3 1 CO 2 1 CO...

Page 9: ...8 2 3 3 3 4 set 40 RH 50 RH 60 RH 70 RH CO 40 RH 40 RH 39 RH 45 RH 50 RH 60 RH 70 RH 40 RH 5 LED 6 1 2...

Page 10: ...9 7 8 1 1H 2H 4H 8H 2 1H 2H 4H 8H 4 5 1 2 3 6 NTC 1 2 10...

Page 11: ...10 30 30 NTC 0 2 NTC 0 2 NTC 1 30 7 3 3 8 8 NTC NTC 3 C8 9 15mm...

Page 12: ...11 10 PDL25 220 240V 50HZ 25L D 30 80 RH 14 5L D 26 7 60 RH 290W 26 7 60 RH 185m 3 h 155m 3 h 200m 3 h R134a 185 g 4 242 x 346 x 590...

Page 13: ......

Page 14: ...IV Operating Introduction 7 1 Control Panel 7 2 Functions Name of Key Pads 7 3 Operation of Key Pads 7 4 Water Full 9 5 Memory function 9 6 Automatic Defrosting 9 7 Compressor protection function 10...

Page 15: ...k 3 Please ensure the unit is not placed closely to the high temperature appliance in prevent of plastic destroying and fire 4 Never operate this unit in an explosive or corrosive atmosphere 5 Always...

Page 16: ...lways switch off at the socket before unplugging to avoid electric shock or arcing 13 Switch off and unplug the unit empty and clean the water reservoir when not using the unit for a long time 14 Do n...

Page 17: ...use it in wet environment or outdoors 3 For the best efficiency and energy saving make sure the door and window are closed before turning on the unit 4 Ensure that the unit is placed on a stable and...

Page 18: ...6 III Components Diagrams Control panel Pull out hook Top cover Lourver Water Tank Window for water level Back casing Continuous drain pipe Removable Filter Cover Front casing Handle...

Page 19: ...ress the button for 3 seconds continuously to switch on off all the lock function of the key pads 3 Operation of Key Pads 1 When user plugs the device into power socket 3 beep signals can be heard ON...

Page 20: ...that the current environment humidity is higher than or equal to 45 RH the appliance start and fan runs at high speed when the appliance detects that the current environment humidity is less than or...

Page 21: ...er turn on again 2 If power failure the machine can not restart automatically and there is no memory function 3 If user set child lock and timer device will shut off when time is up but no memory on c...

Page 22: ...tion The compressor will detect the temperature of the sensor and the temperature on the tube every 8 minutes once the detected result being that the difference between these two temperature rates is...

Page 23: ...Dehumidification 25L D 30 80 RH 14 5L D 26 7 60 RH Power consumption 290W 26 7 60 RH Air circulation High 185m3 h Low 155m3 h Drying 200m3 h Energy Efficiency Grading EEL Grade 1 Refrigerant R134a 18...

Page 24: ......

Reviews: