Connecting equipment to modules
20
Connecting equipment to Variable AC Modules
The Variable AC Module has one variable output for controlling fans, heat mats, heat lamps, or
similar equipment. A temperature probe connector is included for heat mat control. There is also a
connection for a Single-Phase Slave (model
PSU-20
).
The ratings of the equipment
you connect must not exceed
the ratings of the Variable AC
Module.
7 A at 120/230 VAC, general-purpose (resistive)
4.9 FLA at 120/230 VAC, PSC motor
1/2 HP at 120 VAC, 1 HP at 230 VAC
800 W at 120 VAC, 1600 W at 230 VAC
To connect heat mats
When connecting heat mats, you must connect a temperature probe for the master mat.
To connect variable speed fans or heat lamps
Summary of Contents for AutoFlex Connect