PhaseOne H 10 M645 Getting Started Manual Download Page 1

H 10  M645

GETTING STA RT E D

Phase One A/S

Roskildevej 39

DK-2000 Frederiksberg

Denmark

Tel

+45 36 46 01 11

Fax

+45 36 46 02 22

Phase One U.S.

24 Woodbine Ave

Northport, New York

11768

USA

Tel

+00 631-757-0400

Fax

+00 631-757-2217

Summary of Contents for H 10 M645

Page 1: ...GETTING STARTED Phase One A S Roskildevej 39 DK 2000 Frederiksberg Denmark Tel 45 36 46 01 11 Fax 45 36 46 02 22 Phase One U S 24 Woodbine Ave Northport New York 11768 USA Tel 00 631 757 0400 Fax 00 631 757 2217 ...

Page 2: ...espective companies All specifications are subject to change without notice Phase One takes no responsibility for any loss or damage sustained while using their products This manual 2002 Phase One A S Denmark All rights reserved No part of this manual may be reproduced or copied in any way without prior written per mission of Phase One Printed in Denmark Part 80013001 ...

Page 3: ...filter on the CCD 5 3 Getting ready for taking pictures 6 Mounting the viewfinder mask 6 Mounting the H 10 M645 on the Mamiya 645AF 7 Use of cables 8 Using manual focus lenses 9 4 Maintenance 10 Cleaning the IR filter 10 Cleaning between the IR filter and the CCD 10 5 Current limitations 11 Continuos capture mode 11 6 Technical data 12 1 Contents ...

Page 4: ...h telephoto lenses This exiting combination is a result of a joint development project between Phase One and Mamiya OP The functionality of the H 10 M645 is well integrated with the Mamiya 645AFD camera The H 10 M645 camera back communicates with the Mamiya camera through a fast inter nal electrical computer interface The H 10 M645 is based on the highly recognised Phase One camera back technology...

Page 5: ... However this setting can be changed to 100 200 or even 400 ISO inside the Capture One application It is recommended to capture images using a film curve That is done by selecting the film curve in the Capture One software Click the camera icon in the icon bar and select Film Curve or Film Curve Natural Black When capturing with auto exposure modes exposures be tween 1 4000 sec and 30 sec can be o...

Page 6: ...ing this short period of time the CCD must be pro tected from light exposure The H 10 M645 ensures a safe emptying of the CCD by ignoring the shutter release from the Mamiya camera Image orientation detection The CCD in H 10 M645 is positioned in landscape orienta tion Whenever an image is captured in portrait position by rotating the camera an internal sensor detects this new po sition and the im...

Page 7: ...on top of the CCD The filter may not be removed for several reasons l The focusing of the H 10 camera back will be damaged l It is only possible to remount the filter without dust in between the filter and the CCD if you have access to special clean room facilities l The Phase One Product Warranty is terminated ...

Page 8: ... cm x 3 6 cm A H 10 M645 viewfinder mask is provided This mask has to be mounted beneath the original focusing screen The viewfinder mask is positioned in the bracket that holds the focusing screen Please refer to the Mamiya 645 AFD In structions Changing the focus screen before the focus screen is mounted The black mark on the mask must be orien tated to the left front corner of the bracket 6 ...

Page 9: ...0 M645 camera back is pressed well into the locking mecha nism before the upper locking mechanism is pressed to gether Failure to do this can in some circumstances bring the Mamiya camera house in an error state of continuos opening and closing the shutter The same procedure is rec ommended for all film cassettes In case this error appears you simply have to remove the H 10 M645 Notice if the shut...

Page 10: ... cables are required be tween the H 10 M645 and the Mamiya 645AFD when auto focus lenses are used Flash sync cable must be connected to the Mamiya 645AFD camera house When using AF lenses the flash sync cable must NOT be connected to the camera back CORRECT NOT CORRECT ...

Page 11: ...posure 1 60 sec 1 3 f stop 1 125 sec 1 2 f stop 1 250 sec 1 f stop Operating the camera from the host computer The supplied motor cable must be connected between the M connector on the H 10 M645 and the 8 pin connector on the Mamiya camera house AF lenses as well as manual fo cus lenses can be used The provided short flash sync cable shall be con nected between the C plug on the H 10 M645 and the ...

Page 12: ...bed in the guidelines for the CCD cleaning kit that came with your camera back Cleaning between the CCD and the IR filter Do not try to clean between the CCD and the IR filter The mounting of the IR filter is done at the factory in a high class clean room This process is a very specialised process that insures an extremely high quality of the glass surfaces of the CCD and the IR filter The screws ...

Page 13: ...1 5 Current limitations Continuous capture mode Continuous capture mode will work as single exposure mode Keeping the release bottom down will only result in one exposure The release button has to be depressed be tween exposures ...

Page 14: ...double exposure l Orientation sensor for correct display of landscape and portrait images Resolution 3992 x 2656 pixels Image modes RGB Grey or CMYK Pixel depth 3 x 8 bit or 3 x 16 bit for RGB 8 bit or 16 bit for Grey 4 x 8 bit or 4 x 16 bit for CMYK Image area 24 6 mm x 36 9 mm 1 x 1 5 Computer connection IEEE 1394 Power consumption 7 watt Compatible strobe systems When using Auto Focus lenses pl...

Page 15: ...H 10 M645 Getting Started 13 ...

Reviews: