AxN Configurable Motion Control Platform
26
Wiring and Torque Specification
Connect the 4 wires of the AC power supply cable to the correspond terminals on the P1 port:
T to
T, S to S, R to R and PE to PE
.
Cable Fixing
Use a hose clamp to fix the cable on the cable support. For AxN 09.20.4 drive, the nominal torque
to tight these terminals is 0.5 ~ 0.6 N
∙
m.
AC Power Supply Cable Installation
4.2.4
DC Power Supply Input
DC Power Supply Requirement
Main Supply
AxN 09.20.4
Voltage
565V
Type
DC power
Fluctuation of Voltage
0 ~ 800V
Nominal Current Output
9A
Peak Current Output
20A
Nominal Power at 565V
6.3KW
Peak Power at 565V
13.8KW
Note: please do not install filters, reactors and other equipment between DC power and AxN
drive. Connect DC power and AxN drive directly with the power line.