background image

 
 

Operation Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Digital Vibration Tester 

Model No. DVM-1000 

 

Phase II Machine & Tool, Inc. 

283 Veterans Blvd 

Carlstadt, NJ. 07072 

(201) 933-6300 

www.phase2plus.com

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for DVM-1000

Page 1: ...igital Vibration Tester Model No DVM 1000 Phase II Machine Tool Inc 283 Veterans Blvd Carlstadt NJ 07072 201 933 6300 www phase2plus com www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ...ions Acceleration Peak Value 0 1 200 m s or 0 3 656 ft m s Frequency Range 10Hz 1KHz Frequency Range 10Hz 10KHz Velocity RMS RMS 0 01 400 mm s or 0 004 16 0 inch s Frequency Range 10Hz 1KHz Displacement Peak to Peak 0 001 4 00 mm or 0 04 160mil Frequency Range 10Hz 500Hz RPM revolution 60 999 990 r min readings should be multiplied by 10 if the display is set for 10 Frequency 1 20KHz Accuracy 5 2 ...

Page 3: ... 3 4 Hold Key 3 5 Power Key 3 6 Inch Metric Conversion 3 7 Function Key 3 8 Filter Key 3 9 Volume Key 3 11 Stinger Probes 3 12 Magnetic adapter 3 1 3 2 3 6 3 8 3 7 3 5 3 4 3 3 3 11 3 10 3 9 3 12 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 4: ...steel disc or washer may be cemented to a non magnetic surface to permit usage of the magnetic base For Maximum accuracy of Acceleration g measurements the accelerometer should be temporarily mounted on the machine surface with the supplied M5 threaded mounting stud Measurements made in more than one vibration mode can reveal something of the nature of the vibration signal A high acceleration read...

Page 5: ...al you must multiply the value by 10 c Displacement This parameter is typically used on low speed machines because of it s good low frequency response This is NOT recommended for monitoring bearings Units are measured in Mil or mm equivalent peak peak Calibration The DVM does not need a scheduled daily weekly monthly calibration performed however the calibration should be verified yearly by Phase ...

Page 6: ...with regard to securing reliable long term operation of the machine ISO 10816 3 separates the working conditions into four zones Zone A Green Vibration values from machines just put into operation Zone B Yellow Continuous operation without any restrictions Zone C Orange Condition is acceptable only for a limited period of time Zone D Red Dangerous vibration values Damage could occur at any time It...

Page 7: ...eration B Continuous operation without any restrictions C Condition is acceptable only for a limited period of time D Dangerous vibration values Damage could occur at any time www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 8: ... 63 6 NEMA MG1 20 52 Maximum vibration of high power induction motor RPM Rev Displacement p p µm 3000 25 4 1500 2999 50 8 1000 1499 63 6 999 76 2 Example of Analysis chart it s highly suggested that you design your own chart based upon your testing procedure and application www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...