Warning Type of Malfunction / Cause
Possible Cause
Possible Clearance
A13
- Filling failure at the start of
steaming in the first 3
minutes, i.e. lower and
upper water levels not
reached (e.g. during initial
start-up)
- Solenoid valve error
- Level sensor error
(Symptom: Water emerges
from the drain pipe during
steam operation)
- Steam module error
- Ball valve before steam
generator closed
- Filter in connection bracket
of steam generator clogged
- Insufficient on-site water
supply
- Solenoid valve defective or
disconnected
- Level sensor defective or
disconnected
- Steam module defective or
no voltage supply
- Open ball valve
- Clean filter in connection
bracket
- Ensure sufficient water
supply
- Replace solenoid valve
membrane or connect
cable (cable on steam
module with “Fill” marking)
- Replace level sensor or
connect cable (cable on
steam module with “Level”
marking)
- Replace steam module or
connect cable (cable on
steam module with “Mains
230V” marking)
A14
- Filling at the start of
steaming in the first 3
minutes insufficient, i.e.
lower water level reached,
but not upper water level
- Ball valve before steam
generator closed
- Filter in connection bracket
of steam generator clogged
- Insufficient on-site water
supply
- Solenoid valve defective or
disconnected
- Open ball valve
- Clean filter in connection
bracket
- Ensure sufficient water
supply
- Replace solenoid valve
membrane or connect
cable (cable on steam
module with “Fill” marking)
A16
- Maximum cabin
temperature of 55°C
exceeded
- Safety cut-out when
maximum allowed cabin
temperature exceeded
- Allow cabin to cool down
A17
- Drain process of steam
generator defective
- Generator calcified, i.e. drain
outlet and / or pipe clogged
- Remove generator and
clean generator including
drain pipe
A18
- Measured values from
cabin temperature sensor
out of tolerance
- Cabin temperature sensor
defective or disconnected
- Replace or connect cabin
temperature sensor
A19
- Steam generator is filled up
or is filled particular when
starting
- Solenoid valve defective
(untight)
- Clean solenoid valve
membrane or replace it
K Iv SteaM PluS control
Italiano
Summary of Contents for WellSpring 130
Page 3: ... Pharo WellSpring 130 29620xxx Deutsch Masse English Dimensions Italiano Ingombri ...
Page 5: ... 4 1 2 3 9 5 6 7 8 Deutsch English Italiano ...
Page 11: ...Pharo WellSpring 130 29620xxx F 11 Deutsch English Italiano ...
Page 19: ...19 A B F C M K L E N D J I H G Q P O R Deutsch English Italiano ...
Page 21: ...21 2 1 A B D C Deutsch English Italiano ...
Page 23: ...23 2 3 1 D E F D E F 4 G H I G H I Deutsch English Italiano ...
Page 25: ...25 2 3 A B C D F E G 1 4 Deutsch English Italiano ...
Page 27: ...27 1 D E F Deutsch English Italiano ...
Page 29: ...29 1 2 TWW TWW TWK 4 3 Deutsch English Italiano ...
Page 31: ...31 1 2 Deutsch English Italiano ...
Page 33: ...33 3 2 A B C D 1 Deutsch English Italiano ...
Page 35: ...35 2 E M G H K I L 1 E F G H K I Deutsch English Italiano ...
Page 37: ...37 A B C 1 2 4 3 b 5 H K I 3 a D E G F Deutsch English Italiano ...
Page 39: ...39 2 A B C D 1 Deutsch English Italiano ...
Page 41: ...41 2 G H F I H 1 D E F 4 3 Deutsch English Italiano ...
Page 43: ...43 2 3 B A B A 4 4x B A Deutsch English Italiano ...
Page 45: ...45 1 2 C D Deutsch English Italiano ...
Page 47: ...2 3 47 1 Deutsch English Italiano ...
Page 49: ...49 1 2 C SW 3mm A B D Deutsch English Italiano ...
Page 51: ...1 4 51 2 3 A B 5 B C 15mm 6mm 1 2 Deutsch English Italiano ...
Page 53: ...1 53 2 Deutsch English Italiano ...
Page 55: ...55 A B C 1 a D E A B C 1 b D E F F Deutsch English Italiano ...
Page 57: ...57 A B D C 1 2 3 E F 4 G 5 H Deutsch English Italiano ...
Page 59: ...59 G E C D B F A I H O P R S 6 7 4 2 3 1 5 L K N M Deutsch English Italiano ...
Page 61: ...61 A 1 2 C B D 3 F E G H Deutsch English Italiano ...
Page 63: ...63 D C B A 3 1 2 4 E 5 F Deutsch English Italiano ...
Page 65: ...65 1 2 A B C Deutsch English Italiano ...
Page 67: ...67 B A D C Deutsch English Italiano ...
Page 69: ...69 A E G G F F 1 2 3 4 5 6 B H D C E D C Deutsch English Italiano ...
Page 71: ...71 A B B A B D C C 1 2 3 4 5 B 6 Deutsch English Italiano ...
Page 73: ...D C A B 73 Deutsch English Italiano ...
Page 75: ...75 A E B C D 1 A 3 2 A 4 Deutsch English Italiano ...
Page 77: ...77 C 4 1 A 4 3 4 2 C D C D C 5 E D Deutsch English Italiano ...
Page 79: ...79 C D 5 2 6 E D 5 3 C D C 5 1 E E D Deutsch English Italiano ...
Page 85: ...85 Deutsch English Italiano ...
Page 87: ...87 4 1 2 3 A F E G C B 5 D Deutsch English Italiano ...
Page 89: ...89 1 1 A B 1 2 A B C D 2 E Deutsch English Italiano ...
Page 91: ...91 2 3 1 Deutsch English Italiano ...
Page 93: ...93 1 a c d e b 3 a b 4 A 5 a b 2 Deutsch English Italiano ...
Page 95: ...95 1 4 2 3 5 7 A 9 6 10 1 2 4 3 8 Deutsch English Italiano ...
Page 96: ......
Page 97: ......