![PFU Limited fi-6130 Maintenance Manual Download Page 223](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731223.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
223
/
257
Section 8-6-8
8-6-8 IM HOLDER ASSY3/FPC CABLE
- Refer to Section 8-4-7 for the part number of the IM HOLDER ASSY3.
- Refer to Section 8-4-9 for the part number of the FPC CABLE.
<Removal-IM HOLDER ASSY3>
1. Remove the Imprinter.
(1) Referring to Section 8-6-4 “Removing Imprinter,” remove the Imprinter.
2. Remove the Print section cover.
(2) Referring to steps (2) ~ (4) of Section 8-6-6 “IM PINCH ASSY3,” remove the Print section cover.
3. Remove the PR HARNESS and FPC CABLE (plastic).
(3) Referring to step (3) of Section 8-6-7 “IMP JNT,” disconnect the PR HARNESS and FPC CABLE.
4. Remove the IM HOLDER ASSY3.
(4) - Pull the FPC CABLE (plastic) out of the opening on the frame, and withdraw it to the IM HOLDER ASSY3 side. 1
- Remove the E-ring (circle below) on the IM HOLDER ASSY3 shaft. 2
- Disconnect the IM HOLDER ASSY3 shaft in the direction of the arrow, and then remove the IM HOLDER ASSY3. 3
* To remove the FPC CABLE, go to next page.
<Installation-FPC CABLE>
Follow the removing procedure in reverse.
FPC CABLE (plastic)
IM HOLDER ASSY3 shaft
IM HOLDER ASSY3
IM HOLDER ASSY3
1
2
3