Pfeuffer 1336 0821 Installation And Operating Instructions Manual Download Page 1

Artikelnummer / Article no. 

1336 0821 

 

Pfeuffer GmbH 

Flugplatzstraße 70 
97318 Kitzingen 
GERMANY 

Phone: 

+49 9321 9369

Fax: 

+49 9321 9369

50 

Email: 

[email protected] 

Revision 3/10.07.2017

 

Internet:  http://www.pfeuffer.com 

Translation of the original operating instructions

 

Installation and 

Operating instructions 

 

 

 

Summary of Contents for 1336 0821

Page 1: ...lugplatzstra e 70 97318 Kitzingen GERMANY Phone 49 9321 9369 0 Fax 49 9321 9369 50 Email info pfeuffer com Revision 3 10 07 2017 Internet http www pfeuffer com Translation of the original operating in...

Page 2: ...ed utilised without express permission which also applies to communicating its content Offenders are liable to the payment of damages All rights reserved with regard to patent claims or submission of...

Page 3: ...the single keys and indications 9 5 2 Switch on 9 5 3 Menu Installation Configuration 9 5 4 Configuration probes 11 5 5 Reset 12 5 6 EXCEL file 12 5 7 Auto Off Sec 12 6 Routine operation 13 6 1 Measur...

Page 4: ...0 system is designed exclusively for the temperature measurement in grain stores Other applications are not allowed without permission of the manufacturer These operating instructions draw your attent...

Page 5: ...ructions and especially the chapter regarding safety The operator is obliged to use the GTM 800 system only in perfect condition The operator of the GTM 800 system is responsible for the safety device...

Page 6: ...itoring system type GTM 800 Should this be contradictory to your explosion protection document please contact us prior to the installation Please check whether you are subject to the directions of the...

Page 7: ...ly by means of a photo graph Does the supplied instrument show any scratches dents or other damages on the supplied instrument 3 2 Equipment supplied Check the equipment supplied with regard to comple...

Page 8: ...ossible to carry out control measurements more selectively The GTM 800 may only be operated with the protective bag It prevents the battery from falling out of the housing when the device falls down T...

Page 9: ...the single keys and indications 5 2 Switch on Press the central key 5 3 Menu Installation Configuration Select the menu item Settings by means of the arrow keys and confirm by pressing the central ke...

Page 10: ...appears in order to protect the configuration from unintended modifications Set code by entering the figure 2 by means of the arrow keys and confirm it by means of the central key Then enter the figu...

Page 11: ...central key Select Number of probes and confirm by pressing the central key Increase the figure until the number of probes is reached A value from 0 to 200 is permitted At the end of the setting the s...

Page 12: ...figuration of the interface as well as the use of a terminal program If you have any questions please contact Pfeuffer GmbH 5 7 Auto Off Sec Auto Off Sec regulates the period time the GTM 800 remains...

Page 13: ...ate the measurement The proceeding is the same for the measurement of the other probes 6 2 Indicate measurement Move to Indicate by means of the arrow keys and confirm by pressing the central key Prob...

Page 14: ...the instrument and the adapter must be available IR module at GTM 800 Printer LX 300 from the bottom side with IR module and adapter Now select the menu Print and confirm by pressing the central key...

Page 15: ...GmbH 7 Other settings 7 1 Menu Basic settings Select the menu item Settings by means of the arrow keys and confirm by pressing the central key Then select the menu item Basic settings and confirm by...

Page 16: ...umerical value above the selection arrow by one figure Confirm the requested setting by means of the central key The same proceeding is valid for the submenu Time The submenu Reset time deletes the da...

Page 17: ...the central key The voltage of a new 9 V compound battery is 9 4 V 9 V We recommend replacing the battery at a voltage of 7 0 V at least however when the message Battery empty see chapter 8 trouble s...

Page 18: ...s 7 1 6 Menu Language Allows the language selection German English Press the central key to activate this option The selection is done by means of the arrow keys Confirm by pressing the central key 7...

Page 19: ...llumination Activate this menu item by pressing the central key The illumination is switched on or off 7 2 2 Menu Brightness Allows the setting of the illumination intensity Confirm this menu item by...

Page 20: ...l trouble shooting Problems and solutions Error message Cause Battery is empty Confirm error message by means of the central key and replace the battery or charge the accumulator see chapter 7 1 3 You...

Page 21: ...9 3 Temperature measuring probes The probes are marked according to category II 3 D c T4 10 Glossary GTM 800 Hand held unit for the configuration and evaluation of temperature probes Measuring probes...

Page 22: ...itle 2014 35 EU EU Directive Low voltage DIN EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements DIN EN 610101 Safety requirements for electrical equipment for...

Reviews: