2.4 Product usage limits
Parameter
Okta
Installation location
● Indoors, protected against:
─ dust deposits
─ falling objects
─ fire-fighting water
● Outdoors, protected against:
─ falling objects
─ direct influence of weather such as rain, splash water,
strong drafts and sunlight
─ fire-fighting water
─ lightning strike
Installation altitude
max. 2000 m above sea level
1)
Ambient temperature
+5 °C – +40 °C
Relative humidity of air
max. 85 % (depending on the motor version)
Gas temperature, pressure side,
max.
+200
℃
Intake pressure, max.
< 1300 hPa (abs.)
Orientation
Horizontal
Tbl. 3:
Usage limits of the vacuum pump
2.5 Proper use
► Use the vacuum pump for vacuum generation only.
► When pumping media with an oxygen concentration level of > 21 %, only use perfluorinated, syn-
thetic oils (F5) as lubricant.
► Use sealing gas as appropriate for the process.
► Operate the vacuum pump within the application limits of the product and in compliance with the
technical data.
► Adhere to the installation, commissioning, operating, and maintenance instructions.
► Use only accessory parts recommended by Pfeiffer Vacuum.
2.6 Foreseeable improper use
Improper use of the product invalidates all warranty and liability claims. Improper use is any, even unin-
tended, use, which is contrary to the product purpose; and in particular:
● Transport, installation or operation of the vacuum pump in an impermissible spatial position
● Pumping media which are corrosive to materials of the vacuum pump
● Pumping of explosive media
● Pumping radioactive media
● Pumping media prone to exothermic reactions
● Pumping media that introduce an ignition source to the suction chamber
● Pumping media that form adhesive deposits inside the suction chamber and cause the pistons to
touch or jam
● Pumping fluids - flushing media for cleaning are permissible
● Using the vacuum pump to generate pressure
● Using the vacuum pump in systems in which sporadic loads and vibrations or periodic forces act
on the unit
● Use of the vacuum pump in potentially explosive atmospheres
● Use of the vacuum pump in areas with strong electrical, magnetic or electromagnetic fields
● Use of the vacuum pump with open vacuum and/or fore-vacuum flange open to the atmosphere
● Using lubricants not specified by Pfeiffer Vacuum
● Lifting the vacuum pump without the prescribed eye bolts, for example on piping.
1)
at installation altitudes > 1,000m above m.s.l. and an ambient temperature of 40 °C the rated power of the