Problem
Possible causes
Remedy
Unusual noises during opera-
tion
● Defective valves or dia-
phragms
● If necessary, clean or replace the
valves and diaphragms.
● Soiled suction chamber
● Clean suction chamber.
● Valves dirty or defec-
tive
● If necessary, clean or replace the
valves and diaphragms.
● Connection rod or mo-
tor bearing defective
● Contact
.
Tbl. 8:
Troubleshooting on diaphragm pumps
LED
Fig. 10:
LED on the circuit board
LED flashing
Meaning
1×
Supply voltage < 16 V
2×
Supply voltage > 36 V
3×
Electronics excess temperature
4×
Pump blocked, no rotation possible
5×
Error speed monitoring
6×
-
7×
Electronics error
Tbl. 9:
LED display of error codes
Malfunctions