Type designation extended
HiPace® 80 Neo
with TC 80
HiPace® 80 Neo
with TC 80
HiPace® 80 Neo
with TC 80
Max. connection pressure (abs.) for
venting/sealing gas valve
1500 hPa
1500 hPa
1500 hPa
Integral leakage rate
1 · 10
-8
Pa m³/s
1 · 10
-8
Pa m³/s
1 · 10
-8
Pa m³/s
Relative humidity of air
5 – 85 %, non-con-
densing
5 – 85 %, non-con-
densing
5 – 85 %, non-
condensing
Protection degree
IP54, Type 12
IP54, Type 12
IP54, Type 12
Permissible radial magnetic field
max.
3.7 mT
3.7 mT
3.7 mT
Permissible axial magnetic field
max.
23 mT
23 mT
23 mT
Permissible irradiated thermal out-
put max.
1.2 W
1.2 W
1.2 W
Shipping and storage temperature
-25 – 55 °C
-25 – 55 °C
-25 – 55 °C
Weight
1.7 kg
1.7 kg
3.1 kg
Tbl. 18:
Technical data for HiPace 80 Neo, other connection flanges for the output are option-
al
14.3 Substances in contact with the media
Substances in contact with the media
Aluminum alloy
Stainless steel
Rare-earth magnets
Carbon-fiber-reinforced plastic
Epoxy resin
FKM
Nickel
Felt
Operating fluid (ester oil)
Oxide ceramic, as required
Tbl. 19:
Materials that make contact with the process media
14.4 Dimensions
Dimensions in mm
Technical data and dimensions
54/58