Fig. 8:
Mounting orientation: Vertical direction of flow
Fig. 9:
Mounting orientation: Horizontal direction of flow
5.3 Filling with lubricant
NOTICE
Property damage from using non-approved lubricant
Attainment of product-specific performance data is not ensured. If non-approved lubricants are used,
all liability and warranty claims against Pfeiffer Vacuum are excluded.
► Use approved lubricant only.
► Use alternative, application-specific lubricants only following consultation with Pfeiffer Vacuum.
The lubricant type is specified on the rating plate
► Please refer to rating plate of the vacuum pump for type and quantity of intended lubricant.
– Only the lubricant used during initial installation is permissible.
► Contact Pfeiffer Vacuum if you want to use another type of lubricant.
Permissible lubricants
● D1 (standard lubricant)
● P3, optional
● Other lubricants on request
Required consumables
● Lubricant of the vacuum pump
Installation
24/66
Summary of Contents for HILOBE 2704
Page 1: ...OPERATING INSTRUCTIONS EN Translation of the Original HILOBE 2704 4504 6204 Roots pump...
Page 65: ...65 66...
Page 66: ...Notizen Notes...
Page 67: ......